Sale!

PACi Standard 4 Way 90×90 Cassette Inverter – Single Phase R32

£1,194.24 - £2,100.48 ex. VAT

Clear

Note: All systems must be installed by Certified Installer.

Description

Indoor UnitS-60PU2E5BS-71PU2E5BS-100PU2E5BS-125PU2E5BS-140PU2E5B
Outdoor UnitU-60PZ2E5U-71PZ2E5U-100PZ2E5U-125PZ2E5U-140PZ2E5
Nominal Cooling (Range)kW6.0 (2.0 – 7.1)7.1 (2.0 – 7.7)10.0 (3.0 – 11.5)12.5 (3.2 – 13.5)14.0 (3.3 – 15.0)
UK Cooling (Total – Sensible)kW6.7 – 4.67.5 – 5.010.7 – 7.612.6 – 8.413.9 – 9.2
Nominal Heating (Range)kW6.0 (1.8 – 7)7.1 (1.8 – 8.1)10.0 (3.0 – 14.0)12.5 (3.3 – 15.0)14.0 (3.4 – 16.0)
UK HeatingkW5.76.11113.613.7
SEER – SCOP (Cooling – Heating)7.6 – 4.77.6 – 4.76.80 – 4.406.75 – 4.016.51 – 3.89
Energy Efficiency Class (Cool / Heat)A++ / A++A++ / A++A++ / A+NANA
EER – COP (Cooling – Heating)4.00 – 4.723.50 – 4.363.82 – 4.933.58 – 4.433.23 – 4.18
Energy Label (Cooling / Heating)A / AA /AA / AA / AA / A
Annual Electricity Cons. (Cool – Heat)kWh/a276 – 1787327 – 1787515 – 3182NANA
Pdesign (Cooling – Heating at -10°C)kW6.0 – 6.07.1 – 6.010.0 – 10.012.5 – 12.514.0 – 14.0
Heating Capacity at -7°C / -15°CkWTBCTBCNANANA
Operating Range – Cooling°C-10°C to 43°C-10°C to 43°C-10°C to 43°C-10°C to 43°C-10°C to 43°C
Operating Range – Heating°C-15°C to 24°C-15°C to 24°C-15°C to 24°C-15°C to 24°C-15°C to 24°C
Indoor Unit (Grille) Dimensions H-W-Dmm256(33.5)x840(950)x840(950)256 (33.5) x 840 (950) x 840 (950)319 (33.5) – 840 (950) – 840 (950)
Outdoor Unit Dimensions (H-W-D)mm695 x 875 x 320695 x 875 x 320996 x 980 x 370996 x 980 x 370996 x 980 x 370
Weight (Indoor (Grille) – Outdoor)kg20 (5) – 4420 (5) – 4425 (5) – 9025 (5) – 9425 (5) – 94
Indoor Unit Airflow Rate (L-M-H)l/s217 – 260 – 350217 – 260 – 360300 – 430 – 600317 – 450 – 617330 – 483 – 630
Moisture Removal Volumel/h1.72.52.74.86.0
Outdoor Unit Airflow Rate (Cool – Heat)l/s667 – 750834 – 7501166 – 12661300 – 14331383 – 1483
Indoor Sound Pressure (L-M-H)dB(A)28 – 31 – 3628 – 31 – 3732 – 38 – 4533 – 39 – 4634 – 40 – 47
Outdoor Sound Pressure (Cool – Heat)dB(A)46 – 4849 – 4952 – 5255 – 5556 – 56
Pipe Sizes (Gas – Liquid)in5/8″ – 3/8″5/8″ – 3/8″5/8″ – 3/8″5/8″ – 3/8″5/8″ – 3/8″
Pipe Limits (Min-Max Run/Height Diff.)m3 – 40 / 15 – 30*3 – 40 / 15 – 30*5 – 50 / 15 – 30*5 – 50 / 15 – 30*5 – 50 / 15 – 30*
Pre-Charged Form3030303030
R32 Charge (Factory – Additional)kg – g/m1.45 – 351.45 – 352.6 – 452.98 – 452.98 – 45
GWP (Tonnes CO2 Equivalent)0.9790.9791.762.012.01
Suitable For Replacement Tech.YesYesYesYesYes
Indoor Drain ConnectionmmVP25 (32mm OD)VP25 (32mm OD)VP25 (32mm OD)VP25 (32mm OD)VP25 (32mm OD)
Power Supply (Outdoor / Indoor)V-Ph-Hz230 – 1 – 50 / 230 – 1 – 50230 – 1 – 50 / 230 – 1 – 50230 – 1 – 50 / 230 – 1 – 50230 – 1 – 50 / 230 – 1 – 50230 – 1 – 50 / 230 – 1 – 50
Interconnecting Cables2 core**2 core**2 core**2 core**2 core**
Running Current (Cooling – Heating)A7.05 – 5.959.50 – 7.7011.5 – 8.8515.6 – 12.619.5 – 15.0
Input Power (Cooling – Heating)kW1.50 – 1.272.03 – 1.632.62 – 2.033.49 – 2.824.34 – 3.35
Suggested Fuse Size (Outdoor / Indoor)A20A / 5A20A / 5A32 / 5A32 / 5A32 / 5A

Additional information

PACI 4 Way Cassette Standard Inverter - Single Phase R32

Up to 100 sq.m. room – S-100PU2E5B U-100PZ2E5, Up to 125 sq.m. room – S-125PU2E5B U-125PZ2E5, Up to 140 sq.m. room – S-140PU2E5B U-140PZ2E5, Up to 60 sq.m. room – S-60PU2E5B U-60PZ2E5, Up to 70 sq.m. room – S-71PU2E5B U-71PZ2E5