Indoor unit | FDU100VF2 | FDU125VF | FDU140VF | FDU200VG | FDU250VG | |||
Outdoor unit | FDC100VSA | FDC125VSA | FDC140VSA | FDC200VSA | FDC250VSA | |||
Power source | 3 Phase 380-415V, 50Hz / 380V, 60Hz | 3 Phase 380-415V, 50Hz / 380V, 60Hz | ||||||
Nominal cooling capacity (Min~Max) | kW | 10.0 (4.0 ~11.2) | 12.5 (5.0~14.0) | 14.0 (5.0~14.5) | 19.0 (5.2~22.4) | 24.0 (6.9~28.0) | ||
Nominal heating capacity (Min~Max) | kW | 11.2 (4.0~12.5) | 14.0 (4.0~16.0) | 16.0 (4.0~16.5) | 22.4 (3.3~25.0) | 27.0 (5.5~31.5) | ||
Power consumption | Cooling/Heating | kW | 2.80 / 3.02 | 3.90 / 3.88 | 4.95 / 4.69 | 6.15 / 6.03 | 7.98 / 7.20 | |
EER/COP | Cooling/Heating | 3.57 / 3.71 | 3.21 / 3.61 | 2.83 / 3.41 | 3.09 / 3.71 | 3.01 / 3.75 | ||
Inrush current | A | 5 | 5 | 5 | 5 | 5 | ||
Max. current | 16 | 18 | 19 | 25 | 27 | |||
Sound power level*1 | Indoor | Cooling/Heating | dB(A) | 65 / 65 | 67 / 67 | 70 / 70 | 75 / 75 | 75 / 75 |
Outdoor | Cooling/Heating | 70 / 70 | 72 / 72 | 73 / 73 | 72 / 74 | 73 / 75 | ||
Sound pressure level*1 1 | Indoor | Cooling (Hi/Me/Lo) | 38 / 36 / 30 | 40 / 34 / 29 | 40 / 35 / 30 | 50 / 47 / 45 | 50 / 47 / 45 | |
Heating (Hi/Me/Lo) | 38 / 36 / 30 | 40 / 34 / 29 | 40 / 35 / 30 | 50 / 47 / 45 | 50 / 47 / 45 | |||
Outdoor | Cooling/Heating | 49 / 49 | 50 / 51 | 51 / 51 | 57 / 59 | 59 / 62 | ||
Air flow 1 | Indoor | Cooling (Hi/Me/Lo) | m3/min | 28 / 25 / 19 | 32 / 26 / 20 | 35 / 28 / 22 | 72 / 64 / 56 | 72 / 64 / 56 |
Heating (Hi/Me/Lo) | 28 / 25 / 19 | 32 / 26 / 20 | 35 / 28 / 22 | 72 / 64 / 56 | 72 / 64 / 56 | |||
Outdoor | Cooling/Heating | 75 / 73 | 75 / 73 | 75 / 73 | 135 / 135 | 143 / 151 | ||
External static pressure*2 | Pa | Standard:60 Max:200 | Standard:72 Max:200 | |||||
Exterior dimensions | Indoor | HeightxWidthxDepth | mm | 280 x 1,370 x 740 | 379 x 1,600 x 893 | |||
Outdoor | 845 x 970 x 370 | 1,300 x 970 x 370 | 1,505 x 970 x 370 | |||||
Net weight | Indoor | kg | 54 | 89 | ||||
Outdoor | 83 | 115 | 143 | |||||
Ref.piping size | Liquid/Gas | ømm | 9.52(3/8″) / 15.88(5/8″) | 9.52(3/8″) / 22.22(7/8″) | 12.7(1/2″) / 25.4(1″) | |||
Refrigerant line (one way) length | m | Max.50 | Max.70 | |||||
Vertical height differences | Outdoor is higher/lower | m | Max.30 / Max.15 | |||||
Outdoor operating temperature range | Cooling | °C | -15~43*3 | -15~50*3 | ||||
Heating | -20~20 | -15~20 | ||||||
Air filter | Procure locally | |||||||
Remote control (option) | wired:RC-EX3, RC-E5, RCH-E3 wireless:RCN- KIT4-E2 |