Ceiling Floor Convertible Split Systems R410A

  • Full Systems (Indoor + Outdoor Units + Remote Controller)

From: £1,089.00£1,124.00


Note: All systems must be installed by Certified Installer.

Description

INDOOR CV09 NE2 CV12 NE2
Capacity Cooling Min / Nom / Max kW 1.0 / 2.5 / 2.8 1.3 / 3.3 / 3.6
Heating Min / Nom / Max kW 1.2 / 3.0 / 3.3 1.5 / 3.8 / 4.2
Low Temperature Capacity Heating -7°C Max kW 3.1 3.4
Power Input (Set) Cooling Nom kW 0.75 1.09
Heating Nom kW 0.83 1.18
Power Input (Indoor) Nom W 30 40
Running Current Cooling / Heating Nom A 3.26 / 3.61 4.74 / 5.13
Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50
EER 3.33 3.03
COP 3.61 3.22
SEER 5.11 5.31
SCOP 3.81 3.81
Pdesign (@ -10°C) kW 3.0 3.0
Seasonal Energy Label Cooling / Heating A / A A / A
Annual Energy Consumption Cooling / Heating kWh 172 / 1,102 218 / 1,102
Piping Connection Liquid mm Ø6.35 (1/4) Ø6.35 (1/4)
Gas mm Ø9.52 (3/8) Ø9.52 (3/8)
Drain O.D. / I.D. mm 21.5 / 16.0 21.5 / 16.0
Air Flow Rate High / Medium / Low m³/min 7.6 / 6.9 / 6.2 9.2 / 7.6 / 6.6
Sound Pressure Cooling High / Medium / Low dBA 38 / 35 / 32 40 / 36 / 31
Sound Power Cooling Max dBA 52 56
Dehumidification Rate l/h 1.2 1.2
Dimensions Body W x H x D mm 900 x 490 x 200 900 x 490 x 200
Net Weight Body kg 13.7 13.7

 

OUTDOOR UU09W ULD UU12W ULD
Compressor                            Type Rotary Rotary
Airflow Rate Nom m³/min 32 32
Sound Pressure Cooling Nom dBA 47 47
Heating Nom dBA 48 48
Sound Power Cooling Max dBA 56 57
Dimensions W x H x D mm 770 x 540 x 245 770 x 540 x 245
Net Weight kg 32.0 32.0
Refrigerant Type R410A R410A
Charge g 1,000 1,000
Additional Charge g/m 20 20
GWP 2,087.5 2087.5
TCO2eq 2.1 2.1
Operation Range (Outdoor) Cooling Min ~ Max °C DB -10 ~ 43 -10 ~ 43
Heating Min ~ Max °C WB -18 ~ 18 -18 ~ 18
Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50
Power Supply Cable No. x mm² 3C x 2.5 3C x 2.5
Transmission Cable No. x mm² 4C x 0.75 4C x 0.75
Maximum Running Current A 4.9 6.9
Maximum Circuit Breaker Rating A 15 15
Piping Length Total Min ~ Max m 5 ~ 15 5 ~ 15
Piping Elevation Difference IDU – ODU Max m 10 10
Piping Connection Liquid mm (inch) Ø6.35 (1/4) Ø6.35 (1/4)
Gas mm (inch) Ø9.52 (3/8) Ø9.52 (3/8)