Wall Mounted TE – Compact Inverter R410A

From: £656.00£1,544.00 ex. VAT


Note: All systems must be installed by Certified Installer.

Description

Kit KIT-TE20-TKE KIT-TE25-TKE KIT-TE35-TKE KIT-TE42-TKE KIT-TE50-TKE KIT-TE60-TKE
Cooling capacity Nominal (Min-Max) kW 2.00 (0.75 – 2.40) 2.50 (0.85 – 3.00) 3.50 (0.85 – 3.90) 4.20 (0.85 – 4.60) 5.00 (0.98 – 5.60) 6.30 (0.98 – 7.10)
UK Cooling capacity      Total / Sensible kW 1.88 / 1.86 2.29 / 2.23 3.29 / 2.91 3.84 / 3.17 4.45 / 4.05 5.76 / 4.94
EER 1) Nominal (Min-Max) W/W 3.77 (3.00 – 3.75)A 3.73 (3.40 – 3.30)A 3.43 (3.33 – 3.22)A 3.28 (3.21 – 2.75)A 3.36 (3.44 – 3.20)A 3.20 (3.50 – 2.93)A
SEER 2) W/W 6.10 i 6.10 i 6.10 i 5.60 h 6.50 i 6.20 i
Pdesign (cooling) kW 2,0 2,5 3,5 4,2 5,0 6,3
Input power cooling Nominal (Min – Max) kW 0.53 (0.25 – 0.64) 0.67 (0.25 – 0.91) 1.02 (0.26 – 1.21) 1.28 (0.27 – 1.67) 1.49 (0.29 – 1.75) 1.97 (0.28 – 2.42)
Annual energy consumption (ErP) 3) kWh/a 115 143 201 263 269 356
Heating capacity Nominal (Min-Max) kW 2.70 (0.70 – 3.60) 3.30 (0.80 – 4.10) 4.00 (0.80 – 5.10) 5.00 (0.80 – 6.80) 5.80 (0.98 – 7.80) 7.20 (0.98 – 8.50)
UK Heating capacity kW 2,51 2,91 3,61 4,70 2,55 3,05
Heating capacity at -7°C kW 2,14 2,70 3,30 3,90 4,66 5,24
COP 1) Nominal (Min-Max) W/W 3.97 (3.78 – 3.43)A 4.07 (4.10 – 3.57)A 3.74 (4.00 – 3.54)A 3.65 (4.00 – 3.29)A 3.72 (2.88 – 3.36)A 3.38 (2.88 – 3.13)B
SCOP 2) W/W 4.00 h 4.10 h 4.10 h 3.80 a 4.10 h 4.00 h
Pdesign at -10°C kW 1,9 2,4 2,8 3,6 4,0 4,6
Input power heating      Nominal (Min-Max) kW 0.68 (0.19 – 1.05) 0.81 (0.20 – 1.15) 1.07 (0.20 – 1.44) 1.37 (0.20 – 2.07) 1.56 (0.34 – 2.32) 2.13 (0.34 – 2.74)
Annual energy consumption (ErP) 3) kWh/a 665 820 956 1326 1366 1610
Indoor unit   CS-TE20TKEW CS-TE25TKEW CS-TE35TKEW CS-TE42TKEW CS-TE50TKEW CS-TE60TKEW
Air volume Cool/Heat m³/min 10.0 / 10.9 10.9 / 11.6 11.8 / 12.5 12.3 / 12.9 19.9 / 20.8 20.8 / 21.4
Moisture removal volume L/h 1,3 1,5 2,0 2,4 2,8 3,5
Cool (Hi / Lo / Q-Lo) dB(A) 37 / 25 / 20 40 / 26 / 20 42 / 30 / 20 44 / 31 / 29 44 / 37 / 34 45 / 37 / 34
Sound pressure 4) Heat (Hi / Lo / Q-Lo) dB(A) 38 / 26 / 22 40 / 27 / 22 42 / 33 / 22 44 / 35 / 28 44 / 37 / 34 45 / 37 / 34
Dimension H x W x D mm 290 x 799 x 197 290 x 799 x 197 290 x 799 x 197 290 x 799 x 197 302 x 1102 x 244 302 x 1102 x 244
Net weight kg 8 8 8 8 12 12
Outdoor unit   CU-TE20TKE CU-TE25TKE CU-TE35TKE CU-TE42TKE CU-TE50TKE CU-TE60TKE
Power source V 230 230 230 230 230 230
Recommended fuse A 16 16 16 16 16 16
Connection indoor /outdoor mm² 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5
Air volume Cool / Heat m³/min 31.2 / 29.7 30.0 / 28.9 28.7 / 30.4 33.6 / 34.0 33.0 / 33.9 42.6 / 41.5
Sound pressure 4) Cool / Heat (Hi) dB(A) 46 / 47 47 / 48 48 / 50 49 / 51 48 / 49 49 / 49
Dimension 5) H x W x D mm 542 x 780 x 289 542 x 780 x 289 542 x 780 x 289 619 x 824 x 299 619 x 824 x 299 695 x 875 x 320
Net weight kg 26 27 32 32 40 42
Piping connections Liquid pipe Inch (mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)
Gas pipe Inch (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 1/2 (12.70) 1/2 (12.70) 1/2 (12.70)
Pipe length range m 3 ~ 15 3 ~ 15 3 ~ 15 3 ~ 15 3 ~ 20 3 ~ 20
Elevation difference (in/out) 6) m 15 15 15 15 15 15
Pipe length for additional gas m 7,5 7,5 7,5 7,5 7,5 7,5
Additional gas amount g/m 15 15 20 20 20 20
Refrigerant (R410A) kg/TCO2Eq. 0.66 / 1.378 0.77 / 1.608 0.95 / 1.984 1.01 / 2.109 1.38 / 2.881 1.34 / 2.798

Additional information

Wall Mounted TE - Compact - Inverter

, , , , ,

Reviews

There are no reviews yet.

Be the first to review “Wall Mounted TE – Compact Inverter R410A”

Downloads

No files uploaded.