Wall Mounted Split Systems – Standard Inverter R410A

From: £700.00£1,673.00


Note: All systems must be installed by Certified Installer.

Description

Indoor UnitsFTXS20KFTXS25KFTXS35KFTXS42KFTXS50KFTXS60GFTXS71G
CapacityUK Total CoolingkW1,952,443,424,114,565,866,94
UK Sensible CoolingkW1,651,822,562,853,143,874,65
Nominal CoolingkW2,02,53,54,25,06,07,1
Nominal HeatingkW2,53,44,05,45,87,08,2
Seasonal Efficiency (EN14825) COOLINGEnergy LabelA++A++A++A++A++AA
PdesignkW2,02,53,54,25,06,07,1
SEER7,407,907,476,806,805,585,23
Annual Energy ConsumptionkWh95111164216257376475
Seasonal Efficiency (EN14825) HEATINGEnergy LabelA++A++A++A+A+AA
PdesignkW2,32,53,54,04,64,86,5
SCOP4,774,784,854,204,203,893,50
Annual Energy ConsumptionkWh67573210391334153517282593
Nominal EfficiencyEER/COP4.65 / 4.724.39 / 4.674.07 / 4.763.56 / 4.123.55 / 4.003.02 / 3.433.02 / 3.22
Air Flow Rate (Cooling)High / Nom / Low / Silentm3/sec0.147 / – / 0.078 / 0.0650.152 / – / 0.083 / 0.0650.187 / – / 0.097 / 0.0680.187 / – / 0.117 / 0.0680.198 / – / 0.123 / 0.0750.267 / – / 0.188 / 0.1680.287 / – / 0.192 / 0.175
DimensionsHeightmm289289298298298290290
Widthmm78078090090090010501050
Depthmm215215215215215250250
Weightkg881111111212
Sound Pressure (Cooling)High/Nom/Low/SilentdBA40 / 32 / 24 / 1941 / 33 / 25 / 1945 / 37 / 29 / 1945 / 39 / 33 / 2146 / 40 / 34 / 2345 / 41 / 36 / 3346 / 42 / 37 / 34
Sound Pressure (Heating)High/Nom/Low/SilentdBA40 / 32 / 27 / 1940 / 32 / 27 / 1941 / 33 / 27 / 1941 / 33 / 27 / 1945 / 37 / 29 / 1944 / – / 35 / 3246 / – / 37 / 34
Sound Power (Cooling)dBA58585959606063
Outdoor UnitsRXS20L3RXS25L3RXS35L3RXS42LRXS50LRXS60LRXS71F8
Dimensions HeightxWidthxDepthmm550 x 765 x 285550 x 765 x 285735 x 825 x 300770 x 900 x 320
Weightkg34343439474871
Electrical DetailsPower Supply1ph1ph
Running CurrentA2,303,104,105,706,308,8010,49
Starting CurrentA2,43,34,36,66,89,411,7
Max Fuse SizeA10101020202020
Interconnection Wiring       Core / Cable size3+E / 1.53+E / 1.5
Piping Connections            Liquid / Gasinches (mm)1/4 (6.4) / 3/8 (9.5)1/4 (6.4) / 1/2 (12.7)1/4 (6.4) / 5/8 (15.9)
PipeworkMaximum Lengthm20202020303030
Maximum Vertical Risem15151515202020
Precharged tom10101010101010
Additional Chargeg/m2020
Holding Chargekg1,001,001,201,301,701,502,30
Sound Pressure (Cooling)    High / Low / SilentdBA46 / 4346 / 4348 / 4448 / 4448 / 4449 / 4652 / 49
Sound Pressure (Heating)    High / Low / SilentdBA46 / – / 4346 / – / 4348 / – / 4548 / – / 4548 / – / –48 / – / –52 / – / 49
Sound Power (Cooling)59596161626265
Operating Range (Cooling)   Min / Max°CDB-10 / 46-10 / 46-10 / 46-10 / 46-10 / 46-10 / 46-10 / 46
Operating Range (Heating)  Min / Max°CWB-15 / 18-15 / 18-15 / 18-15 / 18-15 / 18-15 / 18-15 / 18
Air Flow Rate (Cooling)        Highm3/sec0,5580,5580,6000,6210,8480,8350,910

Reviews

There are no reviews yet.

Be the first to review “Wall Mounted Split Systems – Standard Inverter R410A”

Your email address will not be published. Required fields are marked *

Downloads

No files uploaded.