Wall Mounted LMCE Range

From: £650.00£981.00 ex. VAT


Note: All systems must be installed by Certified Installer.

Description

Model No. Indoor unit ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE
Outdoor unit AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE
Power Source Single-phase,~230V,50Hz
Nominal Capacity Cooling kW 2.0(0.5-3.0) 2.5(0.5-3.2) 3.4(0.9-3.9) 4.0(0.9-4.4)
Heating 3.0(0.5-3.4) 3.2(0.5-4.0) 4.0(0.9-5.3) 5.0(0.9-6.0)
UK Total/Sensible Cooling 1.94/1.30 2.42/1.59 3.30/2.14 3.87/2.52
Power Consumption Cooling/Heating kW 0.465/0.685 0.65/0.73 0.97/1.02 1.135/1.365
EER Cooling W/W 3,85 3,50 3,52
COP Heating 4,38 4,38 3,92 3,66
Pdesign Cooling/Heating(-10°C) kW 2.00/2.30 2.50/2.40 3.40/3.50 4.00/3.90
SEER Cooling W/W 6,80 7,00 7,00 6,90
SCOP Heating (Average) 4,10 4,10 4,00 4,00
Class
Cooling A++ A++ A++ A++
Heating (Average) A+ A+ A+ A+
Annual Energy Consumption Cooling kWh/a 103 125 170 203
Heating 786 820 1225 1365
Moisture Removal I/h 1,00 1,30 1,80 2,10
Sound Pressure Level Indoor (Cooling) H/M/L/Q dB(A) 43/40/32/21 43/40/32/21 43/40/32/21 44/40/33/25
Indoor (Heating) H/M/L/Q 43/38/33/22 43/38/33/22 43/38/33/22 44/40/35/27
Outdoor(Cooling/Heating) High 45/45 45/45 50/50 50/50
Sound Power Level Indoor(Cooling/Heating) High 59/59 59/59 59/59 60/60
Outdoor(Cooling/Heating) High 58/56 58/56 61/61 65/65
Airflow Rate Indoor / Outdoor High m3/h 750/1670 750/1670 750/1830 750/1800
Net Dimensions H x W x D Weight Indoor mm 270×870×204 270×870×204 270×870×204 270×870×204
kg 8,5 8,5 8,5 8,5
Outdoor mm 535×663×293 535×663×293 535×663×293 540×790×290
kg 21 21 26 34
Remote Controller Type Wireless Wireless Wireless Wireless
Interconnecting Cable (Suggested cable size 1.5mm) 3 Core + Earth
Suggested MCB Size Amp 10 10 10 16
Max. Operating Current Cooling/Heating Amp 6.00/7.50 6.00/7.50 6.50/9.00 9.00/10.50
Starting Current Amp 3,30 3,50 4,80 6,30
Power Supply To Outdoor
Connection Pipe Diameter (Gas / Liquid) Inch 3/8 & 1/4 3/8 & 1/4 3/8 & 1/4 1/2 & 1/4
Max Pipe Length (Factory Gas Charge Pipe Length) m 20(15) 20(15) 20(15) 20(15)
Max Height Difference 15 15 15 15
Refrigerant Type R410A R410A R410A R410A
Charge g 700 700 850 1050
Additional Charge g/m 20 20 20 20
Operation Range Cooling °CDB -10 to 43 -10 to 43 -10 to 43 -10 to 43
Heating -15 to 24 -15 to 24 -15 to 24 -15 to 24

Additional information

Wall Mounted - ASYG-LMCE

, , ,

Reviews

There are no reviews yet.

Be the first to review “Wall Mounted LMCE Range”

Downloads

No files uploaded.