SRK ZMP – Standard Series

From: £446.00£646.00


Note: All systems must be installed by Certified Installer.

Description

 

Indoor unitSRK25ZMP-SSRK35ZMP-SSRK45ZMP-S
Outdoor unitSRC25ZMP-SSRC35ZMP-SSRC45ZMP-S
Power source1 Phase, 220 – 240V, 50Hz
Nominal cooling capacity (Min~Max)kW2.5(0.9~2.8)3.2(0.9~3.5)4.5(0.9~4.8)
Nominal heating capacity (Min~Max)kW2.8(0.8~3.9)3.6(0.9~4.3)5.0(0.8~5.8)
Power consumptionCooling/HeatingkW0.78 / 0.7550.995 / 0.9951.495 / 1.385
EER/COPCooling/Heating3.21/3.713.22 / 3.623.01 / 3.61
Inrush current220/230/240 VA3.9 / 3.8 / 3.64.9 / 4.7 / 4.57.0 / 6.7 / 6.4
Max. running current9914
Sound power
level
IndoorCooling/HeatingdB(A)59 / 5860 / 5860 / 64
OutdoorCooling/Heating60 / 5960 / 6065 / 65
Sound pressure levelIndoorCooling (Hi/Me/Lo)45 / 34 / 2347 / 36 / 2346 / 40 / 25
Heating (Hi/Me/Lo)43 / 34 / 2644 / 36 / 2848 / 43 / 32
OutdoorCooling/Heating47 / 4549 / 4852 / 53
Air flowIndoorCooling (Hi/Me/Lo)m3/min10.1 / 7.3 / 4.29.5 / 6.8 / 4.29.0 / 7.2 / 3.8
Heating (Hi/Me/Lo)9.5 / 7.3 / 5.29.6 / 7.4 / 5.512.0 / 9.2 / 6.2
OutdoorCooling/Heating26.0 / 19.725.4 / 20.535.5 / 33.5
Exterior
dimensions
IndoorHeightxWidthxDepthmm262 x 769 x 210
Outdoor540 x 645(+57) x 275595 x 780(+62) x 290
Net weightIndoor / Outdoorkg6.9 / 257.2 / 277.6 / 40
RefrigerantType/GWPR410A / 2088
Chargekg/TCO2Eq0.655 / 1.3680.81 / 1.6911.20 / 2.506
Refrigerant piping sizeLiquid/Gasø mm6.35(1/4″) / 9.52(3/8″)6.35(1/4″) / 12.7(1/2″)
Refrigerant line (one way) lengthmMax. 15Max. 25
Vertical height differencesOutdoor is higher/lowermMax. 10 / Max. 10Max. 15 / Max. 15
Outdoor operating
temperature range
Cooling˚C-15~46
Heating-15~24
Clean filter

Reviews

There are no reviews yet.

Be the first to review “SRK ZMP – Standard Series”

Your email address will not be published. Required fields are marked *

Downloads

No files uploaded.