SEZ-M R410A Ceiling Concealed Ducted System Standard Inverter Heat Pump (Single Phase)

From: £966.00£1,504.00 ex. VAT


Note: All systems must be installed by Certified Installer.

Description

SEZ-M-DA – INDOOR UNITS SEZ-M25DA SEZ-M35DA SEZ-M50DA SEZ-M60DA SEZ-M71DA
CAPACITY (kW) Heating (nominal) 2.9 (1.3-4.5) 4.2 (1.7-5.0) 6.4 (1.7-7.2) 7.4 (2.5-8.0) 8.1 (2.6-10.4)
Cooling (nominal) 2.5 (1.5-3.2) 3.5 (1.4-3.9) 5.1 (2.3-5.6) 5.6 (2.3-6.3) 7.1 (2.8-8.3)
Heating (UK) 2.44 (1.09-3.79) 3.53 (1.43-4.20) 5.38 (1.43-6.05) 6.21 (2.10-6.71) 6.80 (2.18-8.73)
Cooling (UK) 2.45 (1.47-3.14) 3.43 (1.37-3.82) 4.99 (2.25-5.48) 5.49 (2.25-6.18) 6.95 (2.74-8.12)
SHF (nominal) 0.80 0.78 0.78 0.79 0.74
COP / EER (nominal) 3.61 / 3.42 3.72 / 3.47 3.56 / 3.23 3.36 / 3.22 3.57 / 3.21
SCOP / SEER (BS EN14825) 3.8 / 5.3 4.0 / 5.7 3.9 / 5.8 4.1 / 5.3 3.8 / 5.3
ErP ENERGY EFFICIENCY CLASS Heating/Cooling A / A A+ / A+ A / A+ A+ / A A / A
AIRFLOW (l/s) Lo-Mi-Hi 100-117-150 117-150-183 167-217-250 200-250-300 200-267-333
PIPE SIZE mm (in) Gas 9.52 (3/8”) 9.52 (3/8”) 12.7 (1/2”) 15.88 (5/8”) 15.88 (5/8”)
Liquid 6.35 (1/4”) 6.35 (1/4”) 6.35 (1/4”) 6.35 (1/4”) 9.52 (3/8”)
EXTERNAL STATIC PRESSURE (Pa) 5-15-35-50 5-15-35-50 5-15-35-50 5-15-35-50 5-15-35-50
SOUND PRESSURE LEVEL (dBA) Lo-Mi-Hi 22-25-29 23-28-33 29-33-36 29-33-37 29-34-39
SOUND POWER LEVEL (dBA) 50 53 57 58 60
DIMENSIONS (mm) Width x Depth x Height 790 x 700 x 200 990 x 700 x 200 990 x 700 x 200 1190 x 700 x 200 1190 x 700 x 200
WEIGHT (kg) 18 21 23 27 27
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
FUSE RATING (BS88) – HRC (A) 6 6 6 6 6
INTERCONNECTING CABLE No. Cores 4 4 4 4 4
WIRED REMOTE CONTROLLER REFERENCE PAR-33MAA PAR-33MAA PAR-33MAA PAR-33MAA PAR-33MAA
SUZ-KA-VA6  – OUTDOOR UNITS SUZ-KA25VA6 SUZ-KA35VA6 SUZ-KA50VA6 SUZ-KA60VA6 SUZ-KA71VA6
SOUND PRESSURE LEVEL (dBA) Heating/Cooling 48 / 47 50 / 49 52 / 52 55 / 55 55 / 55
SOUND POWER LEVEL (dBA) Heating/Cooling 58 62 65 65 69
WEIGHT (kg) 30 35 54 50 53
DIMENSIONS (mm) Width x Depth x Height 800 x 285 x 550 800 x 285 x 550 840 x 330 x 880 840 x 330 x 880 840 x 330 x 880
ELECTRICAL SUPPLY 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz 220-240v, 50Hz
PHASE Single Single Single Single Single
SYSTEM POWER
INPUT (kW)
Heating/Cooling (nominal 0.80 / 0.73 1.13 / 1.01 1.80 / 1.58 2.20 / 1.74 2.27 / 2.21
Heating/Cooling (UK) 0.69 / 0.61 0.97 / 0.85 1.55 / 1.33 1.89 / 1.46 1.95 / 1.86
STARTING CURRENT (A) 3.8 5.2 8.2 9.8 10.5
SYSTEM RUNNING CURRENT (A) Heating/Cooling [MAX] 3.50 / 3.80 [7.4] 4.80 / 5.20 [8.7] 7.40 / 8.20 [12.7] 7.70 / 9.80 [14.7] 10.5 / 9.7 [17]
FUSE RATING (BS88) – HRC (A) 10 10 20 20 20
MAINS CABLE No. Cores 3 3 3 3 3
MAX PIPE LENGTH (m) 20 20 30 30 30
MAX HEIGHT DIFFERENCE (m) 12 12 30 30 30
CHARGE REFRIGERANT (kg) / CO2 EQUIVALENT (t)
R410A (GWP 2088) – 7m
0.80 / 1.67 1.15 / 2.40 1.60 / 3.34 1.60 / 3.34 1.80 / 3.76
MAX ADDITIONAL REFRIGERANT (kg) / CO2 EQUIVALENT (t)
R410A (GWP 2088)
0.39 / 0.81 0.39 / 0.81 0.46 / 0.96 0.46 / 0.96 1.265 / 2.64

Additional information

SEZ-M R410A Ceiling Concealed Ducted System Inverter Heat Pump (Single Phase)

, , , ,

Reviews

There are no reviews yet.

Be the first to review “SEZ-M R410A Ceiling Concealed Ducted System Standard Inverter Heat Pump (Single Phase)”

Downloads

No files uploaded.