Indoor UnitRAS-B10U2FVG-EB13U2FVG-EB18U2FVG-E
Outdoor UnitRAS-10PAVSG-E13PAVSG-E18PAVSG-E
NominalCooling CapacitykW2.53.55.0
Heating CapacitykW3.24.26.0
EER/COPW/W4.17/3.723.18/3.362.86/3.00
UKCooling Total/SensiblekW2.44/2.033.42/2.744.40/3.56
HeatingkW1.902.513.43
Cooling EN14825Range Min. – Max.kW0.8 – 3.20.7 – 4.11.0 – 5.6
Power InputkW0.601.101.75
PdesignkW2.53.55.0
SEER/Energy Efficiency Class6.60/A++6.40/A++6.20/A++
Seasonal Energy ConsumptionkWh/a133191282
Heating EN14825Range Min. – Max.kW0.9 – 4.51.0 – 5.21.1 – 6.3
Power InputkW0.861.252.00
PdesignkW2.53.04.0
SCOP/Energy Efficiency Class4.20/A+4.20/A+4.00/A+
Seasonal Energy ConsumptionkWh/a8339991399
Indoor DataRAS-B10U2FVG-EB13U2FVG-EB18U2FVG-E
Air FlowHigh – Lowl/s142 – 72153 – 75178 – 102
High – Lowm3/h510 – 258552 – 270642 – 366
SoundPressure High – LowdB(A)39 – 2340 – 2446 – 31
Power High – LowdB(A)54 – 3855 – 3960 – 46
UnitHeight x Width x Depthmm600 x 700 x 220600 x 700 x 220600 x 700 x 220
Weightkg161616
Pipe ConnectionFlare Connections (gas – liquid)inch3/8 – 1/43/8 – 1/41/2 – 1/4
Drain Pipe Connection OD/IDmm16/1416/1416/14
Remote controllerWH-L16SE (Infra-Red)WH-L16SE (Infra-Red)WH-L16SE (Infra-Red)
Outdoor DataRAS-10PAVSG-E13PAVSG-E18PAVSG-E
Operating RangeCooling/Heating°C-15 to 46/-15 to 24-15 to 46/-15 to 24-15 to 46/-15 to 24
Air FlowHighm3/h – l/s1668 – 4631980 – 5502076 – 576
SoundPressure High Cooling/HeatingdB(A)46/4748/5049/50
Power High Cooling/HeatingdB(A)61/6263/6564/65
UnitHeight x Width x Depthmm550 x 780 x 290550 x 780 x 290550 x 780 x 290
Weightkg282834
Pipe ConnectionFlare Connections (gas – liquid)inch3/8 – 1/43/8 – 1/41/2 – 1/4
Min.-Max. Lengthm2-202-202-20
Maximum Height Differencem±10±10±12
Drain Port Connectionmm161616
Refrigerant R32Base Charge/Chargeless Lengthkg/m0.51/150.67/151.1/15
Additional Chargeg/m202020
Run CurrentMaximumA3.975.228.05
Power CableOutdoor to Indoor3 core + earth3 core + earth3 core + earth
Power SupplySuggested Fuse SizeV/ph/Hz-A220-240/1/50-10220-240/1/50-10220-240/1/50-16

Additional information

RAS Bi-Flow Console Inverter Heat Pump R32

Up to 25 sq.m. room – B10U2FVG-E 10PAVSG-E, Up to 35 sq.m. room – B13U2FVG-E 13PAVSG-E, Up to 50 sq.m. room – B18U2FVG-E 18PAVSG-E

Reviews

There are no reviews yet.

Be the first to review “RAS Bi-Flow Console Inverter Heat Pump R32”

Your email address will not be published. Required fields are marked *

Downloads

No files uploaded.