PEAD-M R410A Ceiling Concealed Ducted System Standard Inverter Heat Pump (Three Phase)

From: £2,158.00£2,691.00 ex. VAT


Note: All systems must be installed by Certified Installer.

Description

PEAD-M – INDOOR UNITS PEAD-M100JA PEAD-M125JA PEAD-M140JA
CAPACITY (kW) Heating (nominal) 11.2 (2.8-12.5) 13.5 (4.8-15.0) 15.0 (4.9-15.8)
Cooling (nominal) 9.4 (3.7-10.6) 12.1 (5.6-13.0) 13.6 (5.8-14.1)
Heating (UK) 9.63 (2.41-10.75) 11.61 (4.13-12.9) 12.9 (4.21-13.59)
Cooling (UK) 8.55 (3.37-9.65) 11.01 (5.1-11.83) 12.38 (5.28-12.83)
SHF (nominal) 0.82 0.84 0.84
COP / EER (nominal) 3.82 / 3.15 3.61 / 2.91 3.51 / 2.61
SCOP (ƞsh) / SEER (ƞsc) (BS EN14825) 4.0 / 5.1 3.77 (150.6%) / 4.82 (192.8%) 3.66 (146.3%) / 4.79 (191.7%)
ErP ENERGY EFFICIENCY CLASS Heating/Cooling A / A+ N/A N/A
AIRFLOW (l/s) Lo-Mi-Hi 400-483-567 492-592-700 533-650-767
PIPE  SIZE mm (in) Gas 15.88 (5/8”) 15.88 (5/8”) 15.88 (5/8”)
Liquid 9.52 (3/8”) 9.52 (3/8”) 9.52 (3/8”)
EXTERNAL STATIC PRESSURE (Pa) 35-50-70-100-150 35-50-70-100-150 35-50-70-100-150
SOUND PRESSURE LEVEL (dBA) Lo-Mi-Hi 29-34-38 33-36-40 34-38-43
SOUND POWER LEVEL (dBA) 62 66 67
DIMENSIONS (mm) Width x Depth x Height 1400 x 732 x 250 1400 x 732 x 250 1600 x 732 x 250
WEIGHT (kg) 39 40 44
ELECTRICAL SUPPLY Fed by Outdoor Unit Fed by Outdoor Unit Fed by Outdoor Unit
FUSE RATING (BS88) – HRC (A) 6 6 6
INTERCONNECTING CABLE No. Cores 4 4 4
WIRED REMOTE CONTROLLER REFERENCE PAR-33MAA PAR-33MAA PAR-33MAA
PUHZ-P – OUTDOOR UNITS PUHZ-P100YKA PUHZ-P125YKA PUHZ-P140YKA
SOUND PRESSURE LEVEL (dBA) Heating/Cooling 54 / 51 56 / 54 57 / 56
SOUND POWER LEVEL (dBA) Cooling 70 72 75
WEIGHT (kg) 78 85 85
DIMENSIONS (mm) Width x Depth x Height 1050 x 330 x 981 1050 x 330 x 981 1050 x 330 x 981
ELECTRICAL SUPPLY 380-415v, 50Hz 380-415v, 50Hz 380-415v, 50Hz
PHASE Three Three Three
SYSTEM  POWER INPUT (kW Heating/Cooling (nominal) 2.93 / 2.98 3.73 / 4.15 4.27 / 5.21
Heating/Cooling (UK) 2.64 / 2.47 3.36 / 3.44 3.84 / 4.32
STARTING CURRENT (A) 2.9 4.0 4.0
SYSTEM RUNNING CURRENT (A) Heating/Cooling  [MAX] 5.5 / 5.4 [11.5] 6.8 / 6.4 [11.5] 8.9 / 7.9 [11.5]
FUSE RATING (BS88) – HRC (A) 16 16 16
MAINS CABLE No. Cores 5 5 5
MAX PIPE LENGTH (m) 50 50 50
MAX HEIGHT DIFFERENCE (m) 30 30 30
CHARGE REFRIGERANT (kg) / CO2 EQUIVALENT (t)
R410A (GWP 2088) – 30m
3.30 / 6.89 3.80 / 7.93 3.80 / 7.93
MAX ADDITIONAL REFRIGERANT (kg) / CO2 EQUIVALENT (t)
R410A (GWP 2088)
1.20 / 2.51 1.20 / 2.51 1.20 / 2.51

Additional information

PEAD-M R410A Ceiling Concealed Ducted System Standard Inverter Heat Pump (Three Phase)

, ,

Reviews

There are no reviews yet.

Be the first to review “PEAD-M R410A Ceiling Concealed Ducted System Standard Inverter Heat Pump (Three Phase)”

Downloads

No files uploaded.