PACi STANDARD Ceiling Inverter+ Single Phase • R410A GAS

From: £1,817.00£2,827.00 ex. VAT


Note: All systems must be installed by Certified Installer.

Description

KIT KIT-60PTY2E5D KIT-71PTY2E5D KIT-100PTY2E5D KIT-125PTY2E5D
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Cooling capacity Nominal (Min – Max) kW 6.0 (2.0 – 7.1) 7.1 (2.0 – 7.7) 10.0 (2.7 – 11.5) 12.5 (3.8 – 13.5)
UK Cooling capacity Total / Sensible kW 6.8 / 5.2 7.4 / 5.6 10.6 / 7.9 12.2 / 8.9
EER Nominal (Min – Max) W/W 3.68 (8.00 – 3.16) A 3.21 (8.00 – 2.91) A 3.01 (5.09 – 2.65) 3.01 (4.22 – 2.62) B
SEER W/W 6.70 A++ 6.10 A++ 6.10 A++ 5.26
Pdesign kW 6.0 7.1 10.0 12.5
Input power cooling Nominal (Min – Max) kW 1.63 (0.25 – 2.25) 2.21 (0.25 – 2.65) 3.32 (0.53 – 4.34) 4.15 (0.90 – 5.16)
Annual energy consumption (ErP) kWh/a 313 407 574
Heating capacity Nominal (Min – Max) kW 6.0 (1.8 – 7.0) 7.1 (1.8 – 8.1) 10.0 (2.1 – 13.8) 12.5 (3.4 – 15.0)
UK Heating capacity kW 6.8 7.9 12.6 14.0
Heating capacity at -7°C /-15°C kW — /— — /— 9.97 / 8.43 10.97 / 9.03
COP Nominal (Min – Max) W/W 4.35 (9.00 – 4.38) A 4.23 (9.00 – 3.77) A 3.85 (5.12 – 3.45) A 3.85 (4.66 – 3.41) A
SCOP W/W 4.00 A+ 4.00 A+ 3.90 A 3.58
Pdesign at -10°C kW 6.0 6.0 10.0 12.5
Input power heating Nominal (Min – Max) kW 1.38 (0.20 – 1.60) 1.68 (0.20 – 2.15) 2.60 (0.41 – 4.00) 3.25 (0.73 – 4.40)
Annual energy consumption (ErP) kWh/a 2100 2100 3590
Indoor unit S-60PT2E5B S-71PT2E5B S-100PT2E5B S-125PT2E5B
Air volume Hi / Med / Lo m³/min 20.0 / 17.0 / 14.5 21.0 / 18.0 / 15.5 30.0 / 25.0 / 23.0 34.0 / 28.0 / 24.0
Sound pressure Hi / Med / Lo dB(A) 38 / 34 / 30 39 / 35 / 31 42 / 37 / 35 46 / 40 / 36
Dimension H x W x D mm 235 x 1275 x 690 235 x 1275 x 690 235 x 1590 x 690 235 x 1590 x 690
Net weight kg 33 33 40 40
Outdoor unit U-60PEY2E5 U-71PEY2E5 U-100PEY1E5 U-125PEY1E5
Power source V 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240
Recommended fuse A 25 30
Connection mm² 4 6
Current  Cool A 8.00 / 7.60 / 7.30 10.80 / 10.30 / 9.85 15.60 / 15.00 / 14.40 19.70 / 18.90 / 18.10
Heat A 6.70 / 6.45 / 6.15 8.20 / 7.85 / 7.50 11.90 / 11.50 / 11.10 15.20 / 14.60 / 13.90
Air volume Cool / Heat m³/min 38 / 41 44 / 41 110 / 95 80 / 73
Sound pressure Cool / Heat (Hi) dB(A) 46 / 48 49 / 49 52 / 52 56 / 56
Dimension H x W x D mm 619 x 799 x 299 619 x 799 x 299 996 x 940 x 340 996 x 940 x 340
Net weight kg 40 40 73 85
Piping connections Liquid pipe Inch (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Gas pipe Inch (mm) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)
Pipe length range m 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50
Elevation difference (in/out) m 30 30 30 30
Pipe length for additional gas m 30 30 30 30
Additional gas amount g/m 40 40 50 50
Refrigerant (R410A) kg / TCO2 Eq. 1.95 / 4.0716 1.95 / 4.0716 2.60 / 5.4288 3.20 / 6.6816
Operating range  Cool Min ~ Max °C -10 ~ +43 -10 ~ +43 -10 ~ +43 -10 ~ +43
Heat Min ~ Max °C -15 ~ +24 -15 ~ +24 -15 ~ +24 -15 ~ +24