KITKIT-71PU2E8DKIT-100PU2E8DKIT-125PU2E8DKIT-140PU2E8D
Remote controllerCZ-RTC5BCZ-RTC5BCZ-RTC5BCZ-RTC5B
Cooling capacityNominal (Min – Max)kW7.1 (3.2 – 8.0)10.0 (3.3 – 12.5)12.5 (3.3 – 14.0)14.0 (3.3 – 15.0)
UK Cooling capacityTotal / SensiblekW7.9 / 6.111.4 / 9.212.7 / 9.914.1 / 10.7
EERNominal (Min – Max)W/W3.94 (5.71 – 3.02) A4.27 (4.29 – 3.38) A3.70 (4.29 – 3.04) A3.30 (4.29 – 2.70) A
SEERW/W7.30 A++7.40 A++6.896.50
PdesignkW7.110.012.514.0
Input power coolingNominal (Min – Max)kW1.80 (0.56 – 2.65)2.34 (0.77 – 3.70)3.37 (0.77 – 4.60)4.24 (0.77 – 5.74)
Annual energy consumption (ErP)kWh/a340473
Heating capacityNominal (Min – Max)kW8.0 (2.8 – 9.0)11.2 (4.1 – 14.0)14.0 (4.1 – 16.0)16.0 (4.1 – 18.0)
UK Heating capacitykW8.114.015.917.8
Heating capacity at -7°C / -15°CkW— /—— /—— /—— /—
COPNominal (Min – Max)W/W4.30 (5.60 – 3.16) A5.00 (5.19 – 3.18) A4.60 (5.19 – 3.17) A4.30 (5.19 – 3.15) A
SCOPW/W4.30 A+4.80 A++4.103.90
Pdesign at -10°CkW7.110.012.514.0
Input power heatingNominal (Min – Max)kW1.86 (0.50 – 2.85)2.24 (0.79 – 4.40)3.04 (0.79 – 5.04)3.72 (0.79 – 5.72)
Annual energy consumption (ErP)kWh/a23122917
Indoor unit  S-71PU2E5BS-100PU2E5BS-125PU2E5BS-140PU2E5B
Air volumeHi / Med / Lom³/min22.0 / 16.0 / 13.036.0 / 26.0 / 18.037.0 / 27.0 / 19.038.0 / 29.0 / 20.0
Sound pressureHi / Med / LodB(A)37 / 31 / 2845 / 38 / 3246 / 39 / 3347 / 40 / 34
Dimension                   Indoor (H x W x D)mm256 x 840 x 840319 x 840 x 840319 x 840 x 840319 x 840 x 840
Panel (H x W x D)mm33.5 x 950 x 95033.5 x 950 x 95033.5 x 950 x 95033.5 x 950 x 950
Net weightIndoor / Panelkg20 / 525 / 525 / 525 / 5
Outdoor unit  U-71PE1E8AU-100PE1E8AU-125PE1E8AU-140PE1E8A
Power sourceV380 / 400 / 415380 / 400 / 415380 / 400 / 415380 / 400 / 415
Recommended fuseA16161616
Connectionmm²2.52.52.52.5
Current CoolA2.80 / 2.70 / 2.603.60 / 3.45 / 3.355.25 / 5.00 / 4.806.65 / 6.30 / 6.10
HeatA2.90 / 2.80 / 2.703.45 / 3.30 / 3.204.75 / 4.50 / 4.355.80 / 5.55 / 5.35
Air volumeCool / Heatm³/min60 / 60110 / 95130 / 110135 / 120
Sound pressureCool / Heat (Hi)dB(A)48 / 5052 / 5253 / 5354 / 55
DimensionH x W x Dmm996 x 940 x 3401416 x 940 x 3401416 x 940 x 3401416 x 940 x 340
Net weightkg71989898
Piping connectionsLiquid pipeInch (mm)3/8 (9.52)3/8 (9.52)3/8 (9.52)3/8 (9.52)
Gas pipeInch (mm)5/8 (15.88)5/8 (15.88)5/8 (15.88)5/8 (15.88)
Pipe length rangem5 ~ 505 ~ 755 ~ 755 ~ 75
Elevation difference (in/out)m30303030
Pipe length for additional gasm30303030
Additional gas amountg/m50505050
Refrigerant (R410A)kg / TCO2 Eq.2.35 / 4.90683.40 / 7.09923.40 / 7.09923.40 / 7.0992
Operating rangeCool Min ~ Max°C-15 ~ +46-15 ~ +46-15 ~ +46-15 ~ +46
Heat Min ~ Max°C-20 ~ +24-20 ~ +24-20 ~ +24-20 ~ +24