Sale!

AOYG Outdoor Units – Up to 2 Rooms

Compare

From: £616.14 - £744.03 ex. VAT

Clear

Description

 Multi Outdoors (2 Way)
  Outdoor AOYG14LAC2 AOYG18LAC2
Nominal Capacity (kW) Cooling 4.00 (1.40-4.40) 5.00 (1.70-5.60)
Heating 4.40 (1.10-5.40) 5.60 (1.80-6.10)
Power Consumption (kW) Cooling 1.09 1.56
Heating 1.03 1.41
EER / COP (Nominal Conditions) 3.67 / 4.27 3.21 / 3.97
Pdesign (kW) @ -10°C Cooling 4.00 5.00
Heating 3.80 4.20
SEER Cooling 6.70 6.60
SCOP Heating (Average) 4.10 4.10
(QHUJ\ (IÀFLHQF\ &ODVV Cooling A++ A++
Heating (Average) A+ A+
Annual Energy Consumption (kWh/a) Cooling 209 265
Heating 1296 1434
Dimensions (HxWxD) mm Outer 540x790x290 540x790x290
Net Weight (kg) Outer 37 38
Room Air Circulation (high) m3/h Inner 1850 2050
Outer 1850 2050
Power Supply V-PH-Hz 230 / 1 / 50 230 / 1 / 50
Power Supply To Outdoor Outdoor
Running Current (A) Cooling 5.12 6.90
Heating 4.91 6.30
Starting Current A 4.90 6.30
Suggested MCB/Fuse A 16 16
Interconnecting Cable 3 + E 3 + E
Sound Pressure (dB(A) Cooling) Cooling 47 50
Heating 49 51
Sound Power (dB(A) Cooling) Cooling 61 63
Heating 63 64
Max Pipe Length m 30 30
Max Height Difference m 15 15
Refrigerant Charge m 20 20
Additional Refrigerant Charge g/m 10 20
Pipe Size (inches) Gas 3/8 x2 3/8 x2
Liquid 1/4 x2 1/4 x2
Operating Range (OC) Cooling 10 ~ 46 10 ~ 46
Heating -15 ~ 24 -15 ~ 24
Refrigerant R410A R410A

Additional information