OUTDOOR UNITMU5M30 U44MU5M40 UO2
Compressor                       TypeTwin RotaryTwin Rotary
Capacity *CoolingMin/Nom/MaxkW1.3/8.8/10.60.9 / 11.2 / 13.5
HeatingMin/Nom/MaxkW1.5/10.1/12.11.0 / 12.5 / 15.0
Low Temperature Capacity    Heating -7°CMaxkW7.111.0
Power Input *CoolingMin/Nom/MaxkW0.4/2.3/3.60.8 / 2.7 / 4.2
HeatingMin/Nom/MaxkW0.6/2.3/3.70.8 / 2.8 / 4.5
Running CurrentCoolingMin/Nom/MaxA1.9/10.2/16.23.5 / 12.1 / 18.4
HeatingMin/Nom/MaxA2.8/10.4/16.83.6 / 12.5 / 19.7
EER3.904.10
COP4.414.45
SEER7.005.80
SCOP4.003.81
Pdesign (@-10°C)kW7.211.8
Seasonal Energy Label          Cooling/HeatingA++/A+A+ / A
Annual Energy Consumption  Cooling/Heating440 / 2520643 / 4,236
Airflow Rate                      Nomm2/min6090
Sound PressureCoolingNomdBA5053
HeatingNomdBA5455
Sound Power                      CoolingMaxdBA6667
Dimensions                        W x H x Dmm950 x 834 x 330950 × 1,170 × 330
Net WeightKg6184.0
RefrigerantType / Charge Kg- TCOR410AR410A
ChargeKg3.23,8
Additional Chargeg/m2020
GWP2,087.52,087.5
t-CO2 eq6.77.9
Operation Range(Outdoor)CoolingMin~Max°C DB-10~48-10 ~ 48
HeatingMin~Max°C WB-18~18-18 ~ 18
Power SupplyØ/V/Hz1/220-240/501 / 220-240 / 50
Power Supply CableNo.xmm23Cx2.53C × 3.5
Transmission CableNo.xmm24Cx0.754C × 0.75
Maximum Running CurrentA16.721.2
Maximum Circuit Breaker RatingA2530
Piping Length Totalm7585
Piping Length per BranchMaxm2525
Piping Elevation DifferenceIDU-ODUMaxm1515
IDU-IDUMaxm7.57.5
Piping ConnectionLiquidmmxNo.Ø6.35 (1/4)x5Ø6.35 (1/4) × 5
GasmmxNo.Ø9.52 (3/8)x5Ø9.52 (3/8) × 5