MU3M Outdoor Units R410A – Up to 3 Rooms

From: £976.00£1,077.00


Note: All systems must be installed by Certified Installer.

Description

OUTDOOR UNITMU3M19 UE4MU3M21 UE4
Compressor                       TypeTwin RotaryTwin Rotary
Capacity *CoolingMin/Nom/MaxkW1.1/5.3/6.31.1/6.2/7.3
HeatingMin/Nom/MaxkW1.2/6.3/7.31.2/7.0/7.8
Low Temperature Capacity    Heating -7°CMaxkW4.44.9
Power Input *CoolingMin/Nom/MaxkW0.3/1.3/1.80.3/1.6/2.2
HeatingMin/Nom/MaxkW0.3/1.5/2.10.3/1.7/2.4
Running CurrentCoolingMin/Nom/MaxA1.2/5.8/8.71.2/7.2/10.0
HeatingMin/Nom/MaxA1.2/6.8/9.71.2/7.7/11.0
EER4.204.00
COP4.304.20
SEER7.607.30
SCOP4.214.21
Pdesign (@-10°C)kW5.25.2
Seasonal Energy Label          Cooling/HeatingA++/A+A++/A+
Annual Energy Consumption  Cooling/Heating243 / 1729283 / 1729
Airflow Rate                      Nomm2/min5050
Sound PressureCoolingNomdBA4950
HeatingNomdBA5454
Sound Power                      CoolingMaxdBA6364
Dimensions                        W x H x Dmm870 x 655 x 320870 x 655 x 320
Net WeightKg4545
RefrigerantType / Charge Kg- TCOR410AR410A
ChargeKg1.71.7
Additional Chargeg/m2020
GWP2,087.52,087.5
t-CO2 eq3.53.5
Operation Range(Outdoor)CoolingMin~Max°C DB-10~48-10~48
HeatingMin~Max°C WB-18~18-18~18
Power SupplyØ/V/Hz1/220-240/501/220-240/50
Power Supply CableNo.xmm23Cx2.53Cx2.5
Transmission CableNo.xmm24Cx0.754Cx0.75
Maximum Running CurrentA12.813.5
Maximum Circuit Breaker RatingA2020
Piping Length Totalm5050
Piping Length per BranchMaxm2525
Piping Elevation DifferenceIDU-ODUMaxm1515
IDU-IDUMaxm7.57.5
Piping ConnectionLiquidmm(inch)xNo.Ø6.35 (1/4)x3Ø6.35 (1/4)x3
Gasmm(inch)xNo.Ø9.52 (3/8)x3Ø9.52 (3/8)x3

Additional information

MU3M (OU) – Up to 3 Rooms

,

Reviews

There are no reviews yet.

Be the first to review “MU3M Outdoor Units R410A – Up to 3 Rooms”

Your email address will not be published. Required fields are marked *

Downloads

No files uploaded.