MU2M Outdoor Units R410A – Up to 2 Rooms

From: £881.00£929.00


Note: All systems must be installed by Certified Installer.

Description

OUTDOOR UNITMU2M15 UL4MU2M17 UL4
Compressor                       TypeTwin RotaryTwin Rotary
Capacity *CoolingMin/Nom/MaxkW0.9/4.1/4.70.9/4.7/5.4
HeatingMin/Nom/MaxkW1.0/4.7/5.41.0/5.3/5.7
Low Temperature Capacity    Heating -7°CMaxkW3.33.7
Power Input *CoolingMin/Nom/MaxkW0.2/1.0/1.40.2/1.3/1.7
HeatingMin/Nom/MaxkW0.2/1.1/1.50.2/1.2/1.7
Running CurrentCoolingMin/Nom/MaxA1.1/4.6/6.41.1/5.6/7.9
HeatingMin/Nom/MaxA1.1/4.9/6.71.1/5.5/7.6
EER4.153.75
COP4.404.25
SEER7.607.50
SCOP4.204.20
Pdesign (@-10°C)kW4.14.1
Seasonal Energy Label          Cooling/HeatingA++/A+A++/A+
Annual Energy Consumption  Cooling/Heating189 / 1367219 / 1367
Airflow Rate                      Nomm2/min28.228.2
Sound PressureCoolingNomdBA4848
HeatingNomdBA5151
Sound Power                      CoolingMaxdBA6163
Dimensions                        W x H x Dmm770 x 545 x 288770 x 545 x 288
Net WeightKg3737
RefrigerantType / Charge Kg- TCOR410AR410A
ChargeKg1.41.4
Additional Chargeg/m2020
GWP2,087.52,087.5
t-CO2 eq2.92.9
Operation Range(Outdoor)CoolingMin~Max°C DB-10~48-10~48
HeatingMin~Max°C WB-18~18-18~18
Power SupplyØ/V/Hz1/220-240/501/220-240/50
Power Supply CableNo.xmm23Cx2.53Cx2.5
Transmission CableNo.xmm24Cx0.754Cx0.75
Maximum Running CurrentA9.49.4
Maximum Circuit Breaker RatingA1515
Piping Length Totalm3030
Piping Length per BranchMaxm2020
Piping Elevation DifferenceIDU-ODUMaxm1515
IDU-IDUMaxm7.57.5
Piping ConnectionLiquidmm(inch)xNo.Ø6.35 (1/4)x2Ø6.35 (1/4)x2
Gasmm(inch)xNo.Ø9.52 (3/8)x2Ø9.52 (3/8)x2

Reviews

There are no reviews yet.

Be the first to review “MU2M Outdoor Units R410A – Up to 2 Rooms”

Your email address will not be published. Required fields are marked *

Downloads