Low Static Pressure Ducted Inverter R410A

From: £1,202.00£1,642.00


Note: All systems must be installed by Certified Installer.

Description

KIT  KIT-E9-PD3EAKIT-E12-QD3EAKIT-E18-RD3EA
Cooling capacityNominal (Min – Max)kW2.50 (0.85 – 3.00)3.40 (0.85 – 4.00)5.10 (0.90 – 5.70)
UK Cooling capacityTotal / SensiblekW2.22 / 1.892.51 / 2.193.61 / 2.79
EERNominal (Min – Max)W/W4.24 (3.54 – 3.95) A3.86 (3.54 – 3.45) A3.19 (3.53 – 3.13) B
SEERW/W5.80 h5.60 h5.80 h
Pdesign (cooling)kW2.503.405.10
Input power coolingNominal (Min – Max)kW0.59 (0.24 – 0.76)0.88 (0.24 – 1.16)1.60 (0.26 – 1.82)
Annual energy consumption (ErP)kWh/a151213308
Heating capacityNominal (Min – Max)kW3.20 (0.85 – 4.60)4.00 (0.85 – 5.10)6.10 (0.90 – 7.10)
UK Heating capacitykW3.173.544.95
Heating capacity at -7°CkW2.603.004.30
COPNominal (Min – Max)W/W3.72 (3.70 – 3.33) A3.54 (3.70 – 3.29) B3.33 (3.46 – 3.26) C
SCOPW/W4.20 h3.80 a3.90 a
Pdesign at -10°CkW2.602.904.00
Input power heatingNominal (Min – Max)kW0.86 (0.23 – 1.38)1.13 (0.23 – 1.55)1.83 (0.26 – 2.18)
Annual energy consumption (ErP)kWh/a86710681436
Indoor unit  CS-E9PD3EACS-E12QD3EAWCS-E18RD3EAW
External static pressureS-Hi / Hi / Me / LoPaN/AN/AN/A
Air volumeCool / Heatm³/min6.9 / 8.19.3 / 10.415.3 / 15.3
Moisture removal volumeL/h1.502.302.80
Cool (Hi / Lo / Q-Lo)dB(A)33 / 27 / 2434 / 27 / 2441 / 30 / 27
Sound pressureHeat (Hi / Lo / Q-Lo)dB(A)35 / 28 / 2536 / 28 / 2541 / 32 / 29
DimensionH x W x Dmm235 x 750 x 370235 x 750 x 370200 x 750 x 640
Net weightkg171719
Outdoor unit  CU-E9PD3EACU-E12QD3EACU-E18RBEA
Power sourceV230230230
Recommended fuseA161616
Connection indoor / outdoormm²4 x 1.5 to 2.54 x 1.5 to 2.54 x 1.5 to 2.5
Sound pressureCool / Heat (Hi)dB(A)47 / 4747 / 4847 / 48
DimensionH x W x Dmm622 x 824 x 299695 x 875 x 320695 x 875 x 320
Net weightkg364547
Piping connectionsLiquid pipeInch (mm)1/4 (6.35)1/4 (6.35)1/4 (6.35)
Gas pipeInch (mm)3/8 (9.52)3/8 (9.52)1/2 (12.70)
Pipe length rangem3 ~ 203 ~ 203 ~ 30
Elevation difference (in/out)m151520
Pipe length for additional gasm7.57.510
Additional gas amountg/m202020
Refrigerant (R410A)kg / TCO2 Eq.
Operating rangeCool Min ~ Max°C-10 ~ +43-10 ~ +43-10 ~ +43
Heat Min ~ Max°C-10 ~ +24-10 ~ +24-10 ~ +24

Additional information

Low Static Pressure Ducted - Inverter

, ,

Reviews

There are no reviews yet.

Be the first to review “Low Static Pressure Ducted Inverter R410A”

Your email address will not be published. Required fields are marked *

Downloads

No files uploaded.