PACi STANDARD Low Static Pressure Hide Away Inverter+ Single Phase • R410A GAS

Compare

From: £1,660.00£2,678.00 ex. VAT

Clear

Description

KIT KIT-60PNY1E5C KIT-71PNY1E5C KIT-100PNY1E5C KIT-125PNY1E5C
Remote controller CZ-RTC5B CZ-RTC5B CZ-RTC5B CZ-RTC5B
Cooling capacity Nominal (Min – Max) kW 6.0 (2.0 – 7.1) 7.1 (2.0 – 7.7) 10.0 (2.7 – 11.5) 12.5 (3.8 – 13.5)
UK Cooling capacity Total / Sensible kW 6.8 / 5.3 7.4 / 5.6 10.6 / 8.5 12.2 / 9.3
EER Nominal (Min – Max) W/W 3.21 (5.00 – 2.78) A 2.76 (5.00 – 2.48) D 2.81 (4.74 – 2.67) C 2.81 (4.00 – 2.60) C
SEER W/W 4.80 B 5.10 A 5.30 A 4.95
Pdesign kW 6.0 7.1 10.0 12.5
Input power cooling Nominal (Min – Max) kW 1.87 (0.40 – 2.55) 2.57 (0.40 – 3.10) 3.56 (0.57 – 4.30) 4.45 (0.95 – 5.20)
Annual energy consumption (ErP) kWh/a 437 487 660
Heating capacity Nominal (Min – Max) kW 6.0 (1.8 – 7.0) 7.1 (1.8 – 8.1) 10.0 (2.1 – 13.8) 12.5 (3.4 – 15.0)
UK Heating capacity kW 6.8 7.9 12.9 14.0
Heating capacity at -7°C /-15°C kW — /— — /— 9.97 10.97
COP Nominal (Min – Max) W/W 3.73 (5.14 – 3.78) A 3.70 (5.14 – 3.31) A 3.41 (4.67 – 3.37) B 3.41 (4.36 – 3.26) B
SCOP W/W 3.80 A 3.80 A 3.80 A 3.52
Pdesign at -10°C kW 5.6 5.6 7.6 12.5
Input power heating Nominal (Min – Max) kW 1.61 (0.35 – 1.85) 1.92 (0.35 – 2.45) 2.94 (0.45 – 4.10) 3.67 (0.78 – 4.60)
Annual energy consumption (ErP) kWh/a 2061 2061 2800
Indoor unit S-60PN1E5A S-71PN1E5A S-100PN1E5A S-125PN1E5A
External static pressure Nominal (Min – Max) Pa 50 (10 – 80) 50 (10 – 80) 50 (10 – 80) 50 (10 – 80)
Air volume Cool / Heat m³/min 22 / 20 / 16 22 / 20 / 16 36 / 33 / 26 38 / 35 / 28
Sound pressure Hi / Med / Lo dB(A) 43 / 41 / 36 43 / 41 / 36 44 / 42 / 37 45 / 43 / 38
Dimension H x W x D mm 250 x 1000 x 650 250 x 1000 x 650 250 x 1200 x 650 250 x 1200 x 650
Net weight kg 32 32 41 41
Outdoor unit U-60PEY2E5 U-71PEY2E5 U-100PEY1E5 U-125PEY1E5
Power source V 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240
Recommended fuse A 25 30
Connection mm² 4 6
Current  Cool A 8.70 / 8.40 / 8.00 12.10 / 11.60 / 11.20 16.00 / 15.30 / 14.80 20.10 / 19.30 / 18.70
Heat A 7.40 / 7.10 / 6.80 9.00 / 8.60 / 8.25 13.00 / 12.50 / 12.10 16.50 / 15.80 / 15.20
Air volume Cool / Heat m³/min 38 / 41 44 / 41 110 / 95 80 / 73
Sound pressure Cool / Heat (Hi) dB(A) 46 / 48 49 / 49 52 / 52 56 / 56
Dimension H x W x D mm 619 x 799 x 299 619 x 799 x 299 996 x 940 x 340 996 x 940 x 340
Net weight kg 40 40 73 85
Piping connections Liquid pipe Inch (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Gas pipe Inch (mm) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)
Pipe length range m 3 ~ 40 3 ~ 40 5 ~ 50 5 ~ 50
Elevation difference (in/out) m 30 30 30 30
Pipe length for additional gas m 30 30 30 30
Additional gas amount g/m 40 40 50 50
Refrigerant (R410A) kg / TCO2 Eq. 1.95 / 4.0716 1.95 / 4.0716 2.60 / 5.4288 3.20 / 6.6816
Operating range  Cool Min ~ Max °C -10 ~ +43 -10 ~ +43 -10 ~ +43 -10 ~ +43
Heat Min ~ Max °C -15 ~ +24 -15 ~ +24 -15 ~ +24 -15 ~ +24

Additional information

PACi STANDARD Low Static Pressure Hide Away Inverter+ Single Phase • R410A GAS

, , ,

Reviews

There are no reviews yet.

Be the first to review “PACi STANDARD Low Static Pressure Hide Away Inverter+ Single Phase • R410A GAS”

Your email address will not be published. Required fields are marked *

Downloads

No files uploaded.