Sale!

Large High Static Ducted (3 Phase) R410A

£3,215.55 - £3,728.95 ex. VAT

Clear

Note: All systems must be installed by Certified Installer.

Description

Indoor UnitAC180JNHPKH/EUAC200KNHPKH/EUAC250KNHPKH/EU
Outdoor UnitAC180JXAPNH/EUAC200KXAPNH/EUAC250KXAPNH/EU
Cooling (Min/Nominal/Max)kW6.00 / 18.0 / 20.07.50 / 20.0 / 23.09.0 / 25.00 / 28.50
Heating up to +7°C (Min/Nominal/Max)kW4.80 / 20.0 / 22.508.50 / 23.00 / 25.0010.0 / 27.00 / 32.00
Heating @ -5°CkW
Heating @ -15°CkW
Energy Efficiency CoolingSEERW/WA
ConsumptionkWh/a
PdesignckW
EERW/W3.303.102.61
Energy Efficiency HeatingSCOPW/WA
ConsumptionkWh/a
Pdesignh (average)kW
COPW/W3.613.453.24
AirFlow RateIndoor Unit (High/Mid/Low)m3/min71.00 /60.00 /50.0072.00 /62.00 /48.0080.00/ 64.00/ 51.00
Sound PowerIndoor UnitdB(A)697072
Outdoor UnitdB(A)767577
Sound PressureIndoor Unit (Silent/Low/Mid/High)dB(A)35/ 39 / 4336 / 340 / 4437 / 42 / 47
Outdoor UnitdB(A)55 / 5758 / 6059 / 61
Fan/ Outdoor unitTypeSiroccoSiroccoSirocco
PowerW630630630
NumberEA222
External Static PressureMin / Std / MaxPa50.01/ 60.02/ 196.1349.03/ 72.00/ 196.1349.03/ 72.00/ 196.13
Operating Temp. RangeCooling°C-15 ~ 50-15 ~ 50-15 ~ 50
Heating°C-20 ~ 24-20 ~ 24-20 ~ 24
Power SourceIndoor UnitV / Hz / Φ/ #220~240/ 50/ 1/ 2220~240/ 50/ 1/ 2220~240/ 50/ 1/ 2
Outdoor Unit 1PV / Hz / Φ/ #
Outdoor Unit 3PV / Hz / Φ/ #380~415/ 50/ 3/ 4380~415/ 50/ 3/ 4380~415/ 50/ 3/ 4
Compressor TypeOutdoor UnitTypeTwin BLDC RotaryBLDC ScrollBLDC Scroll
Power (Min/ Nominal/Max)CoolingkW1.30/ 5.45/ 7.302.10/ 6.45/ 8.002.60/ 9.58/ 12.00
HeatingkW1.20 /5.54/ 7.602.10/ 6.66/ 9.802.50/ 8.33/ 13.50
Cooling- Tri-Phase (Min/Std/Max)A2.30/ 8.40/ 16.103.8/ 10.0/ 12.34.7/ 14.9/ 18.4
Heating- Tri-Phase (Min/Std/Max)A2.20 /8.60/ 16.103.8/ 10.3/ 164.5/ 12.9/ 22
Net Dimensions (W x H x D)Indoor Unitmm1350 x 450 x 9101350 x 450 x 9101350 x 450 x 910
Outdoor Unitmm940 x 1420 x 330940 x 1630 x 460940 x 1630 x 460
Net WeightIndoor Unitkg1350 x 450 x 9101350 x 450 x 91092.0
Outdoor Unitkg107.5154.0154.0
RefrigerantTypeR410A(Contains fluorinated greenhouse gas, GWP=2,088)
Factory chargingkg4.606.606.60
Charging Ton equivalent CO2tCO2e9.60 tCO2e13.78 tCO2e13.78 tCO2e
Additional refrigerant chargingg / m
Piping ConnectionsLiquid PipeΦ.inch3 / 83 / 83 / 8
Gas PipeΦ.inch3 / 43 / 47 / 8
Piping LengthMin/ Maxm757575
Piping HeightMaxm303030
Piping ConnectionsDrain pipeΦ.mmVP25 (OD 32.ID 25)VP25 (OD 32.ID 25)VP25 (OD 32.ID 25)
AccessoiresDrain pumpMDP-G075SP MDP-G075SQDCDC

Additional information

Large High Static Ducted (3 Phase) R410A

Up to 180 sq.m. room – AC180JNHPKH/EU AC180JXAPNH/EU, Up to 200 sq.m. room – AC200KNHPKH/EU AC200KXAPNH/EU, Up to 250 sq.m. room – AC250KNHPKH/EU AC250KXAPNH/EU

Reviews

There are no reviews yet.

Be the first to review “Large High Static Ducted (3 Phase) R410A”

Downloads

No files uploaded.