Free Multi System E Outdoor Units • R410A GAS – Up to 3 Rooms

From: £1,329.00£1,511.00 ex. VAT


Note: All systems must be installed by Certified Installer.

Description

System Capacity (Min – Max Indoor Cooling Capacity Nominal) 4.5 to 9.0kW 4.5 to 11.0kW
Unit   CU-3E18PBE CU-3E23SBE
Cooling capacity Nominal (Min – Max) kW 5.20(1.80-7.30) 6.80(1.90-8.00)
EER W/W 4.33(5.00-3.24) 3.56(7.04-3.38)
SEER W/W 7.00 i 7.00 i
Pdesign (cooling) kW 5.2 6.8
Input power cooling Nominal (Min – Max) kW 1.27(0.36-2.25) 1.91(0.27-2.37)
Annual energy consumption (ErP) kWh/a 260 955
Heating capacity Nominal (Min – Max) kW 6.80(1.60-8.30) 8.50(3.30-10.40)
Heating capacity at -7°C kW 4.90 6.05
COP W/W 4.69(3.93-5.00) 4.07(5.32-3.74)
SCOP W/W 4.00 h 4.00 h
Pdesign at -10°C kW 4.8 5.2
Input power heating Nominal (Min – Max) kW 1.41(0.32-2.18) 2.09(0.62-2.78)
Annual energy consumption (ErP) kWh/a 1680 1820
Current Cool / Heat A 5.30 / 6.70 8.40 / 9.60
Power source V 230 230
Recommended fuse A 16 16
Recommended power cable section mm² 2.5 2.5
Sound pressure Cool / Heat (Hi) dB(A) 46 / 47 50 / 51
Dimension H x W x D mm 795 x 875 x 320 795 x 875 x 320
Net weight kg 71 71
Piping connections Liquid pipe Inch (mm) 1/4 (6.35) 1/4 (6.35)
Gas pipe Inch (mm) 3/8 (9.52) 3/8 (9.52)
Pipe length range total m 6 ~ 50 6 ~ 60
Pipe length range to one unit m 3 ~ 25 3 ~ 25
Elevation difference (in/out) m 15 15
Pipe length for additional gas m 30 30
Additional gas amount g/m 20 20
Refrigerant (R410A) kg / TCO2 Eq. 2.64 / 5.5123 2.64 / 5.5123
Operating range Cool Min ~ Max °C -10 ~ +46 -10 ~ +46
Heat Min ~ Max °C -15 ~ +24 -15 ~ +24