Sale!

Floor / Ceiling Range

Compare

From: £963.27 - £1,197.00 ex. VAT

Clear

Description

IndoorABYG18LVTBABYG24LVTA
OutdoorAOYG18LALLAOYG24LALA
Nominal Capacity (kW)Cooling5.20 (0.90-5.90)6.80 (0.90-8.00)
Heating6.00 (0.90-7.50)8.00 (0.90-9.10)
UK Total / Sensible Cooling *4.79 / 3.336.05 / 4.51
Power Consumption (kW)Cooling1.622.21
Heating1.662.26
EER / COP (Nominal Conditions)3.21 / 3.613.08 / 3.54
Pdesign (kW) @ -10°CCooling5.206.80
Heating5.206.00
SEERCooling6.105.60
SCOPHeating (Average)4.003.90
(QHUJ\ (IÀFLHQF\ &ODVVCoolingA++A+
Heating (Average)A+A
Annual Energy Consumption (kWh/a)Cooling298425
Heating18192150
Moisture Removall/h2.002.70
Dimensions (HxWxD) mmInner199x990x655199x990x655
Outer578x790x300578x790x315
Net Weight (kg)Inner2727
Outer4044
Room Air Circulation (high) m3/hInner780980
Outer20002470
Power SupplyV-PH-Hz230 / 1 / 50230 / 1 / 50
Power Supply ToOutdoorOutdoor
Running Current (A)Cooling7.209.70
Heating7.409.90
Starting CurrentA7.409.90
Suggested MCB/FuseA1616
Interconnecting Cable3 + E3 + E
Remote Control TypeWirelessWireless
Sound Pressure (dB(A) Cooling)Indoor Q/L/M/H31 / 34 / 40 / 4335 / 40 / 44 / 48
Outdoor H5052
Sound Power (dB(A) Cooling)Indoor H5761
Outdoor H6267
Max Pipe Lengthm2530
Max Height Differencem1520
Refrigerant Chargem1515
Additional Refrigerant Chargeg/m2020
Pipe Size (inches)Gas1/25/8
Liquid1/41/4
Operating Range (OC)Cooling-10 ~ 46-10 ~ 46
Heating-15 ~ 24-15 ~24
RefrigerantR410AR410A