Slim Ducted Split Systems R410A

From: £991.00£1,438.00


Note: All systems must be installed by Certified Installer.

Description

Indoor Units FDXM25F3 FDXM35F3 FDXM50F3 FDXM60F3
Capacity UK Total Cooling kW 2.35 3.32 4.81 5.86
UK Sensible Cooling kW 1.81 2.26 3.08 3.97
Nominal Cooling kW 2.4 3.4 5.0 6.0
Nominal Heating kW 3.2 4.0 5.8 7.0
Seasonal Efficiency (EN14825) COOLING Energy Label A+ A A+ A
Pdesign kW 2.4 3.4 5.0 6.0
SEER 5.63 5.21 5.72 5.51
Annual Energy Consumption kWh 149 228 306 381
Seasonal Efficiency (EN14825) HEATING Energy Label A+ A A A
Pdesign kW 2.6 2.9 4.0 4.6
SCOP 4.24 3.88 3.93 3.80
Annual Energy Consumption kWh 858 1047 1425 1693
Nominal Efficiency EER / COP 3.74 / 4.00 2.96 / 3.48 3.03 / 3.10 2.91 / 3.21
Air Flow Rate (Cooling) High / Nom / Low m3/sec 0.145 / 0.145 / 0.122 0.145 / 0.145 / 0.122 0.200 / 0.200 / 0.167 0.267 / 0.000 / 0.225
External Static Pressure Nominal Pa 30 30 40 40
Dimensions Height mm 200 200 200 200
Width mm 750 750 1150 1150
Depth mm 620 620 620 620
Weight kg 21 21 30 30
Sound Pressure (Cooling) High / Nom / Low dBA 35 / 33 / 27 35 / 33 / 27 38 / 36 / 30 38 / 36 / 30
Sound Pressure (Heating) High / Nom / Low dBA 35/33/27 35/33/27 38/35/30 38/35/30
Sound Power (Cooling) dBA 53 53 55 56
Outdoor Units RXS25L3 RXS35L3 RXS50L RXS60L
Dimensions Height x Width x Depth mm 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300
Weight kg 34 34 47 48
Electrical Details Power Supply 1ph
Running Current A 3.90 4.90 7.10 9.20
Starting Current A 3.3 4.3 6.8 10.2
Max Fuse Size A 16 16 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches (mm) 1/4 (6.4) / 3/8 (9.5) 1/4 (6.4) / 1/2 (12.7)
Pipework Maximum Length m 20 20 30 30
Maximum Vertical Rise m 15 15 20 20
Precharged to m 10 10 10 10
Additional Charge g/m 20
Holding Charge kg 1.00 1.20 1.70 1.50
Sound Pressure (Cooling) High / Silent Operation dBA 46 / 43 48 / 44 48 / 44 49 / 46
Sound Pressure (Heating) High / Silent Operation dBA 48/45 48/45 48/- 48/-
Sound Power (Cooling) dBA 61 61 62 62
Operating Range (Cooling) Min / Max °CDB -10 / 46 -10 / 46 -10 / 46 -10 / 46
Operating Range (Heating) Min / Max °CWB -15 / 18 -15 / 18 -15 / 18 -15 / 18
Air Flow Rate (Cooling) High m3/sec 0.558 0.600 0.484 0.836

Reviews

There are no reviews yet.

Be the first to review “Slim Ducted Split Systems R410A”

Your email address will not be published. Required fields are marked *

Downloads

No files uploaded.