Ducted Split Systems – Seasonal Classic R410A

From: £1,911.00£3,025.00 ex. VAT


Note: All systems must be installed by Certified Installer.

Description

Indoor Units Single Phase 3 Phase
FBA71A FBA100A FBA125A FBA140A FBA100A FBA125A FBA140A
Capacity UK Total Cooling kW 7.28 10.80 13.60 14.90 10.80 13.60 14.90
UK Sensible Cooling kW 4.99 7.44 9.30 10.25 7.44 9.30 10.25
Nominal Cooling kW 6.8 9.5 12.0 13.4 9.5 12.0 13.4
Nominal Heating kW 7.5 10.8 13.5 15.5 10.8 13.5 15.5
Seasonal Efficiency (EN14825) COOLING Energy Label A+ A+ A A+ A
Pdesign kW 6.8 9.5 12.0 9.5 12.0
SEER 5.84 5.61 5.47 5.61 5.47
Annual Energy Consumption kWh 408 593 768 593.00 768.00
Seasonal Efficiency (EN14825) HEATING Energy Label A+ A+ A+ A+ A+
Pdesign kW 6.0 7.6 7.6 7.6 7.6
SCOP 4.01 4.15 4.01 4.15 4.01
Annual Energy Consumption kWh 2095 2564 2653 2564 2653
Nominal Efficiency EER / COP 3.43 / 3.92 3.35 / 3.67 3.23 / 3.63 3.06 / 3.40 3.35 / 3.67 3.23 / 3.63 3.06 / 3.40
Air Flow Rate (Cooling) High / Nom / Low m3/sec 0.300 / 0.250 /
0.208
0.483 / 0.433 /
0.383
0.567 / 0.483 /
0.392
0.567 / 0.483 /
0.393
0.483 / 0.433 /
0.383
0.567 / 0.483 /
0.392
0.567 / 0.483 /
0.393
External Static Pressure High / Nom Pa 150 / 30 150 / 40 150 / 50 150 / 40 150 / 50
Dimensions Height mm 245 245 245 245 245 245 245
Width mm 1000 1400 1400 1400 1400 1400 1400
Depth mm 800 800 800 800 800 800 800
Weight kg 35 46 46
Sound Pressure (Cooling) High / Nom / Low dBA 30 / 28 / 25 34 / 32 / 30 37 / 35 / 32 37 / 35 / 32 34 / 32 / 30 37 / 35 / 32 37 / 35 / 32
Sound Pressure (Heating) High / Nom / Low dBA 31 / 28 / 25 36 / 33 / 30 38 / 35 / 32 38 / 35 / 32 36 / 33 / 30 38 / 35 / 32 38 / 35 / 32
Sound Power (Cooling) dBA 56 58 62 62 58 62
Outdoor Units RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1
Dimensions Height x Width x Depth mm 770 x 900 x 320 990 x 940 x 320 1430 x 940 x 320 990 x 940 x 320 1430 x 940 x 320
Weight kg 72 75 75 95 82 82 101
Electrical Details Power Supply 1ph 3ph
Running Current A 8.46 11.73 15.29 18.15 4.39 5.72 6.79
Starting Current A 4.0 4.0 4.0 4.0 4.0 4.0 4.0
Max Fuse Size A 20 32 32 32 20 20 20
Interconnection Wiring Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections Liquid / Gas inches (mm) 3/8 (9.5) / 5/8 (15.9) 3/8 (9.5) / 5/8 (15.9)
Pipework Maximum Length m 50 50 50 50 50 50 50
Maximum Vertical Rise m 15 30 30 30 30 30 30
Precharged to m 30 30 30 30 30 30 30
Additional Charge g/m Refer to Installation Manual Refer to Installation Manual
Holding Charge kg 2.75 2.90 2.90 4.00 2.90 2.90 4.00
Sound Pressure (Cooling) Nom / Night Quiet dBA 49 / 49 53 / 49 54 / 49 53 / 49 53 / 49 54 / 49 53 / 49
Sound Pressure (Heating) Nom / Night Quiet dBA 51 / – 57 / 49 58 / 49 54 / 49 57 / 49 58 / 49 54 / 49
Sound Power (Cooling) dBA 65 70 70 69 70 70 69
Operating Range (Cooling) Min / Max °CDB -15 / 46 -15 / 46 -15 / 46 -15 / 46 -15 / 46 -15 / 46 -15 / 46
Operating Range (Heating) Min / Max °CWB -15 / 15.5 -15 / 15.5 -15 / 15.5 -15 / 15.5 -15 / 15.5 -15 / 15.5 -15 / 15.5
Air Flow Rate (Cooling) High m3/sec 0.866 1.266 1.283 1.383 1.266 1.283 1.383

Reviews

There are no reviews yet.

Be the first to review “Ducted Split Systems – Seasonal Classic R410A”

Downloads

No files uploaded.