Model No. | Outdoor unit | AOYG36LBLA5 | AOYG45LBLA6 | ||
Power Source | Single-phase, ~230V, 50Hz | ||||
Nominal Capacity | Cooling | kW | 10.0 (3.5-12.5) | 12.5 (3.5-14.0) | |
Heating | 12.0 (3.5-14.0) | 13.5 (3.5-16.0) | |||
Power Consumption | Cooling/Heating | kW | 2.44/2.79 | 3.57/3.37 | |
EER | Cooling | W/W | 4,10 | 3,50 | |
COP | Heating | 4,30 | 4,00 | ||
Pdesign | Cooling/Heating(-10°C) | kW | 10.00/9.00 | – | |
SEER | Cooling | W/W | 7,00 | – | |
SCOP | Heating (Average) | 4,40 | – | ||
Class | Cooling | A++ | – | ||
Heating (Average) | A+ | – | |||
Annual Energy Consumption | Cooling | kWh/a | 500 | – | |
Heating | 2859 | – | |||
Sound Pressure Level | Cooling | High | dB(A) | 53 | 53 |
Heating | 55 | 55 | |||
Sound Power Level | Cooling/Heating | High | 67/68 | 67/68 | |
Airflow Rate | Outdoor | High | m3/h | 4200 | 4200 |
Net Dimensions | H x W x D Outdoor | mm | 998×970×370 | 998×970×370 | |
Weight | Outdoor | kg | 94 | 94 | |
Interconnecting Cable (Suggested cable size 1.5mm) | Upto 5 x 3 Core + Earth | Upto 6 x 3 Core + Earth | |||
Suggested MCB Size | Amp | 25 | 30 | ||
Max. Operating Current | Cooling/Heating | Amp | 20,6 | 24 | |
Starting Current | Amp | 12,30 | 15,70 | ||
Power Supply To | Outdoor | ||||
Connection Pipe Diameter | Gas | Inch | 3/8 x3, 1/2 x2 | 3/8 x4, 1/2 x2 | |
Liquid | 1/4 x5 | 1/4 x6 | |||
Max Pipe Length (Factory Gas Charge Pipe Length) | m | 80 (50) | 80 (50) | ||
Max Height Difference | 15 | 15 | |||
Refrigerant | Type | R410A | R410A | ||
Charge | g | 4 000 | 4 000 | ||
Additional Charge | g/m | 20 | 20 | ||
Operation Range | Cooling | °CDB | -10 to 46 | -10 to 46 | |
Heating | -15 to 24 | -15 to 24 |