Sale!

AOYG Outdoor Units – Up to 3 Rooms

Compare

From: £839.79 - £957.60 ex. VAT

Clear

Description

 Multi Outdoors (3 Way)
 OutdoorAOYG18LAT3AOYG24LAT3
Nominal Capacity (kW)Cooling5.40 (1.80-6.80)6.80 (1.80-8.50)
Heating6.80 (2.00-8.00)8.00 (2.00-8.80)
Power Consumption (kW)Cooling1.351.94
Heating1.622.00
EER / COP (Nominal Conditions)4.00 / 4.203.51 / 4.00
Pdesign (kW) @ -10°CCooling5.406.80
Heating5.005.20
SEERCooling6.906.40
SCOPHeating (Average)4.304.20
(QHUJ\ (IÀFLHQF\ &ODVVCoolingA++A++
Heating (Average)A+A+
Annual Energy Consumption (kWh/a)Cooling274372
Heating16271730
Dimensions (HxWxD) mmOuter700x900x330700x900x330
Net Weight (kg)Outer5555
Room Air Circulation (high) m3/hInner30503300
Outer27503300
Power SupplyV-PH-Hz230 / 1 / 50230 / 1 / 50
Power Supply ToOutdoorOutdoor
Running Current (A)Cooling5.908.50
Heating7.108.80
Starting CurrentA7.108.80
Suggested MCB/FuseA1616
Interconnecting Cable3 + E3 + E
Sound Pressure (dB(A) Cooling)Cooling4648
Heating4749
Sound Power (dB(A) Cooling)Cooling6568
Heating6770
Max Pipe Lengthm5050
Max Height Differencem1515
Refrigerant Chargem3030
Additional Refrigerant Chargeg/m2020
Pipe Size (inches)Gas3/8 x2 / 1/2 x13/8 x2 / 1/2 x1
Liquid1/4 x31/4 x3
Operating Range (OC)Cooling-10 ~ 46-10 ~ 46
Heating-15 ~ 24-15 ~ 24
RefrigerantR410AR410A

Additional information

AOYG Outdoor Units – Up to 3 Rooms

,

Reviews

There are no reviews yet.

Be the first to review “AOYG Outdoor Units – Up to 3 Rooms”

Your email address will not be published. Required fields are marked *

Downloads