  Outdoor AOYG18LAT3 AOYG24LAT3
Nominal Capacity (kW) Cooling 5.40 (1.80-6.80) 6.80 (1.80-8.50)
Heating 6.80 (2.00-8.00) 8.00 (2.00-8.80)
Power Consumption (kW) Cooling 1.35 1.94
Heating 1.62 2.00
EER / COP (Nominal Conditions) 4.00 / 4.20 3.51 / 4.00
Pdesign (kW) @ -10°C Cooling 5.40 6.80
Heating 5.00 5.20
SEER Cooling 6.90 6.40
SCOP Heating (Average) 4.30 4.20
(QHUJ\ (IÀFLHQF\ &ODVV Cooling A++ A++
Heating (Average) A+ A+
Annual Energy Consumption (kWh/a) Cooling 274 372
Heating 1627 1730
Dimensions (HxWxD) mm Outer 700x900x330 700x900x330
Net Weight (kg) Outer 55 55
Room Air Circulation (high) m3/h Inner 3050 3300
Outer 2750 3300
Power Supply V-PH-Hz 230 / 1 / 50 230 / 1 / 50
Power Supply To Outdoor Outdoor
Running Current (A) Cooling 5.90 8.50
Heating 7.10 8.80
Starting Current A 7.10 8.80
Suggested MCB/Fuse A 16 16
Interconnecting Cable 3 + E 3 + E
Sound Pressure (dB(A) Cooling) Cooling 46 48
Heating 47 49
Sound Power (dB(A) Cooling) Cooling 65 68
Heating 67 70
Max Pipe Length m 50 50
Max Height Difference m 15 15
Refrigerant Charge m 30 30
Additional Refrigerant Charge g/m 20 20
Pipe Size (inches) Gas 3/8 x2 / 1/2 x1 3/8 x2 / 1/2 x1
Liquid 1/4 x3 1/4 x3
Operating Range (OC) Cooling -10 ~ 46 -10 ~ 46
Heating -15 ~ 24 -15 ~ 24
Refrigerant R410A R410A