600 x 600 4 Way Cassette Inverter – Single Phase R410A

*Grille Included

From: £1,199.00£1,881.00 ex. VAT


Note: All systems must be installed by Certified Installer.

Description

KIT    KIT-E9-PB4EA KIT-E12-PB4EA KIT-E18-RB4EA  KIT-E21-RB4EA
Cooling capacity Nominal (Min – Max) kW 2.50 (0.85 – 3.00) 3.40 (0.85 – 4.00) 5.00 (0.90 – 5.80) 5.90 (0.90 – 6.30)
UK Cooling capacity Total / Sensible kW TBC TBC 4.65 / 3.36 5.49 / 3.65
EER 1) Nominal (Min – Max) W/W 4.55 (3.54 – 4.05) A 3.82 (3.54 – 3.33) A 3.13 (3.53 – 2.97) B 2.88 (3.53 – 2.86) C
SEER 2) W/W 5.80 h 5.60 h 5.80 h 5.60 h
Pdesign (cooling) kW 2.50 3.40 5.00 5.90
Input power cooling Nominal (Min – Max) kW 0.55 (0.24 – 0.74) 0.89 (0.24 – 1.20) 1.60 (0.26 – 1.95) 2.05 (0.26 – 2.20)
Annual energy consumptio n (ErP) 3) kWh/a 151 213 302 369
Heating capacity Nominal (Min – Max) kW 3.20 (0.85 – 4.80) 4.50 (0.85 – 5.60) 5.60 (0.90 – 7.10) 7.00 (0.90 – 8.00)
UK Heating capacity kW TBC TBC 4.97 5.64
Heating capacity at -7°C kW 2.60 3.00
COP 1) Nominal (Min – Max) W/W 4.00 (3.70 – 3.56) A 3.17 (3.70 – 2.80) D 3.01 (3.46 – 2.92) D 2.86 (3.46 – 2.84) D
SCOP 2) W/W 4.00 h 3.80 a 4.10 h 4.10 h
Pdesign at -10°C kW 2.70 3.00 3.80 4.00
Input power heating Nominal (Min – Max) kW 0.80 (0.23 – 1.35) 1.42 (0.23 – 2.00) 1.86 (0.26 – 2.43) 2.45 (0.26 – 2.82)
Annual energy consumptio n (ErP) 3) kWh/a 945 1105 1298 1366
Indoor unit   CS-E9PB4EA CS-E12PB4EA CS-E18RB4EAW CS-E21RB4EAW
Panel CZ-BT20EW CZ-BT20EW CZ-BT20EW CZ-BT20EW
Air volume Cool / Heat m³/min 10.5 / 10.8 10.5 / 10.8 11.5 / 11.8 12.4 / 14.6
Moisture removal volume L/h 1.5 2.3 2.8 3.3
Sound pressure Cool (Hi / Lo / Q-Lo  dB(A)  34 / 26 / 23  34 / 26 / 23  37 / 28 / 25 42 / 33 / 30
Heat (Hi / Lo / Q-Lo  dB(A)  35 / 28 / 25 35 / 28 / 25 38 / 29 / 26  43 / 34 / 31
Dimension (H x W x D) Indoor mm 260 x 575 x 575 260 x 575 x 575 260 x 575 x 575 260 x 575 x 575
Panel mm 51 x 700 x 700 51 x 700 x 700 51 x 700 x 700 51 x 700 x 700
Net weight Indoor / Panel kg 18 / 2.5 18 / 2.5 18 / 2.5 18 / 2.5
Outdoor unit   CU-E9PB4EA CU-E12PB4EA CU-E18RBEA CU-E21RBEA
Power source V 230 230 230 230
Recommended fuse A 16 16 16 16
Connection indoor / outdoo mm² 4 x 1.5 to 2.5 4 x 1.5 to 2.5 4 x 1.5 to 2.5 4 x 1.5 to 2.5
Sound pressure 4) Cool / Heat (Hi) dB(A) 45 / 46 45 / 47 47 / 48 49 / 50
Dimension 5) H x W x D mm 622 x 824 x 299 695 x 875 x 320 695 x 875 x 320 695 x 875 x 320
Net weight kg 36 45 47 47
Piping connections Liquid pipe Inch (mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)
Gas pipe Inch (mm) 3/8 (9.52) 3/8 (9.52) 1/2 (12.70) 1/2 (12.70)
Pipe length range m 3 ~ 20 3 ~ 20 3 ~ 30 3 ~ 30
Elevation difference (in/out) 6) m 15 15 20 20
Pipe length for additional gas m 10 10 10 10
Additional gas amount g/m 20 20 20 20
Refrigerant (R410A) kg / TCO2 Eq.
Operating range Cool Min ~ Max °C -10 ~ +43 -10 ~ +43 -10 ~ +43 -10 ~ +43
Heat Min ~ Max °C -10 ~ +24 -10 ~ +24 -10 ~ +24 -10 ~ +24