Combination | MMY- | AP3816FT8P-UK | AP4016FT8P-UK | AP4216FT8P-UK | |
Model Name Heat Recovery | MMY- | MAP2006FT8P-UK | MAP2006FT8P-UK | MAP1406FT8P-UK | |
MAP1806FT8P-UK | MAP2006FT8P-UK | MAP1406FT8P-UK | |||
MAP1406FT8P-UK | |||||
Capacity Range | hp | 38 | 40 | 42 | |
Maximum Number of Indoor Units | QTY | 64 | 64 | 64 | |
Cooling Capacity | kW | 106.4 | 112.0 | 120.0 | |
Heating Capacity | kW | 114.5 | 116.0 | 135.0 | |
Operating Range Cooling/Heating | °C | -10.0 to 46.0/ -25.0 to 15.5 | -10.0 to 46.0/ -25.0 to 15.5 | -10.0 to 46.0/ -25.0 to 15.5 | |
Cooling | Power Consumption | kW | 34.60 | 37.20 | 38.10 |
EER/SEER/Energy Efficiency Class (or ηsc %) | 3.08/5.81/229.4 | 3.01/5.68/224.2 | 3.15/5.67/223.8 | ||
Heating | Power Consumption | kW | 29.60 | 31.80 | 31.50 |
COP/SCOP/Energy Efficiency Class (or ηsc(A) %) | 3.59/3.60/141.0 | 3.52/3.60/141.0 | 3.81/3.57/139.8 | ||
Fan(s) | Standard Air Flow H | l/s | 4972 + 4806 | 4972 + 4972 | 3389 + 3389 + 3389 |
Standard Air Flow H | m3/h | 17900 + 17300 | 17900 + 17900 | 12200 + 12200 + 12200 | |
External Static Pressure | Pa | 40 | 40 | 40 | |
Sound | Pressure Level C/H | dB(A) | 64.5/65.5 | 64.5/65.5 | 67/69 |
Power Level C/H | dB(A) | 86.5/87.5 | 86.5/87.5 | 86/88 | |
Unit(s) | Height x Width x Depth | mm | 1830 x 3220 x 780 | 1830 x 3220 x 780 | 1830 x 3670 x 780 |
Weight | kg | 377 + 377 | 377 + 377 | 316 + 316 + 316 | |
Refrigerant Base Charge | kg | 11 + 11 | 11 + 11 | 11 + 11 + 11 | |
Pipe Connections | Suction Gas Pipe Brazing | inch | 1-5/8 | 1-5/8 | 1-5/8 |
Discharge Pipe Brazing | inch | 1-3/8 | 1-3/8 | 1-3/8 | |
Liquid Pipe Flare | inch | 7/8 | 7/8 | 7/8 | |
Balance Pipe Flare | inch | 3/8 | 3/8 | 3/8 | |
Maximum | Maximum Equivalent Length | m | 200 | 200 | 200 |
Real Length | m | 180 | 180 | 180 | |
Total Pipe Length (Liquid Line Real Length) | m | 1000 | 1000 | 1000 | |
Length To First Branch Height Difference Between Indoor Units ≤ 3 m | m | 100 | 100 | 100 | |
Length To First Branch Height Difference Between Indoor Units > 3 m | m | 85 | 85 | 85 | |
Equivalent Length Of Outdoor Unit Connecting Pipe | m | 10 | 10 | 10 | |
Real Length Between Single Port FS Unit and Indoor Unit (3 series) | m | 50 (15) | 50 (15) | 50 (15) | |
Real Length Between Multi Port FS Unit and Indoor Unit | m | 50 | 50 | 50 | |
Real Length Of Indoor Unit Connecting Piping | m | 30 | 30 | 30 | |
Equivalent Length Between Branches | m | 50 | 50 | 50 | |
Height Difference Outdoor Higher Than Indoor Units | m | 70 | 70 | 70 | |
Height Difference Outdoor Lower Than Indoor Units | m | 30 | 30 | 30 | |
Height Difference Between Indoor Units | m | 40 | 40 | 40 | |
Height Difference Between Outdoor Units | m | 5 | 5 | 5 | |
Electrical | Voltage Range Minimum/Maximum | V | 342/456 | 342/456 | 342/456 |
Electrical Characteristic Run Current Cooling/Heating | A | 54.28/46.19 | 58.36/49.35 | 59.8/49.4 | |
Power Supply Wiring Starting Current | Soft Start | Soft Start | Soft Start | ||
Power Supply | V/ph/Hz | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | |
Suggested Fused Supply(s) | A | 50 + 40 | 50 + 50 | 32 + 32 + 32 |