Description
Combination | MMY- | AP3816HT8P-E | AP4016HT8P-E | AP4216HT8P-E | AP4416HT8P-E | |
Model Name Heat Pump | MMY- | MAP2206HT8P-E MAP1606HT8P-E | MAP2006HT8P-E MAP2006HT8P-E | MAP2206HT8P-E MAP2006HT8P-E | MAP2206HT8P-E MAP2206HT8P-E | |
Capacity Range | hp | 38 | 40 | 42 | 44 | |
Maximum Number of Indoor Units | QTY | 64 | 64 | 64 | 64 | |
Cooling Capacity | kW | 106.5 | 112.0 | 117.5 | 123.0 | |
Heating Capacity | kW | 114.0 | 126.0 | 127.0 | 128.0 | |
Operating Range Cooling/Heating | °C | -5.0 to 46.0/ -25.0 to 15.5 |
-5.0 to 46.0/ -25.0 to 15.5 |
-5.0 to 46.0/ -25.0 to 15.5 |
-5.0 to 46.0/ -25.0 to 15.5 |
|
Cooling | Power Consumption | kW | 37.5 | 34.6 | 40.5 | 46.4 |
EER/SEER/Energy Efficiency Class (or ηsc %) | 2.84/5.20/205.0 | 3.24/5.74/226.6 | 2.90/5.40/213.0 | 2.65/5.07/199.8 | ||
Heating | Power Consumption | kW | 30.0 | 34.0 | 34.1 | 34.2 |
COP/SCOP/Energy Efficiency Class (or ηsc(A) %) | 3.80/3.59/140.6 | 3.71/3.60/141.0 | 3.72/3.55/139.0 | 3.74/3.49/136.6 | ||
Fan(s) | Standard Air Flow H | l/s | 5139 + 3500 | 4972 + 4972 | 5139 + 4972 | 5139 + 5139 |
Standard Air Flow H | m3/h | 18500 + 12600 | 17900 + 17900 | 18500 + 17900 | 18500 + 18500 | |
External Static Pressure | Pa | 40 | 40 | 40 | 40 | |
Sound | Pressure Level C/H | dB(A) | 64.5/66.5 | 64/65 | 64/65 | 64/65 |
Power Level C/H | dB(A) | 85.5/86.5 | 85/87 | 85.5/87 | 86/87 | |
Unit(s) | Height x Width x Depth | mm | 1830 x 2830 x 780 | 1830 x 3220 x 780 | 1830 x 3220 x 780 | 1830 x 3220 x 780 |
Weight | kg | 371 + 300 | 371 + 371 | 371 + 371 | 371 + 371 | |
Refrigerant Base Charge | kg | 11.5 + 11.5 | 11.5 + 11.5 | 11.5 + 11.5 | 11.5 + 11.5 | |
Pipe Connections | Suction Gas Pipe Brazing | inch | 1-5/8 | 1-5/8 | 1-5/8 | 1-5/8 |
Liquid Pipe Flare | inch | 7/8 | 7/8 | 7/8 | 7/8 | |
Balance Pipe Flare | inch | 3/8 | 3/8 | 3/8 | 3/8 | |
Maximum | Equivalent Length | m | 220 | 220 | 220 | 220 |
Real Length | m | 180 | 180 | 180 | 180 | |
Total Pipe Length (Liquid Line Real Length) | m | 1000 | 1000 | 1000 | 1000 | |
Length To First Branch | m | 100 | 100 | 100 | 100 | |
Equivalent Length Of Outdoor Unit Connecting Pipe | m | 10 | 10 | 10 | 10 | |
Real Length Of Indoor Unit Connecting Piping | m | 30 | 30 | 30 | 30 | |
Equivalent Length Between Branches | m | 50 | 50 | 50 | 50 | |
Height Difference Outdoor Higher Than Indoor Units | m | 70 | 70 | 70 | 70 | |
Height Difference Outdoor Lower Than Indoor Units | m | 40 | 40 | 40 | 40 | |
Height Difference Between Indoor Units | m | 40 | 40 | 40 | 40 | |
Height Difference Between Outdoor Units | m | 5 | 5 | 5 | 5 | |
Electrical | Voltage Range Minimum/Maximum | V | 342/456 | 342/456 | 342/456 | 342/456 |
Electrical Characteristic Run Current Cooling/Heating | A | 58.00/46.70 | 53.60/52.20 | 62.40/52.60 | 71.20/53.00 | |
Power Supply Wiring Starting Current | Soft Start | Soft Start | Soft Start | Soft Start | ||
Power Supply | V/ph/Hz | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | |
Suggested Fused Supply(s) | A | 50 + 40 | 40 + 40 | 50 + 40 | 50 + 50 |