Description
Combination | MMY- | AP2816HT8P-E | AP3016HT8P-E | AP3216HT8P-E | AP3416HT8P-E | AP3616HT8P-E | |
Model Name Heat Pump | MMY- | MAP1606HT8P-E MAP1206HT8P-E | MAP1606HT8P-E MAP1406HT8P-E | MAP1606HT8P-E MAP1606HT8P-E | MAP1806HT8P-E MAP1606HT8P-E | MAP2006HT8P-E MAP1606HT8P-E | |
Capacity Range | hp | 28 | 30 | 32 | 34 | 36 | |
Maximum Number of Indoor Units | QTY | 63 | 64 | 64 | 64 | 64 | |
Cooling Capacity | kW | 78.5 | 85.0 | 90.0 | 95.4 | 101.0 | |
Heating Capacity | kW | 87.5 | 95.0 | 100.0 | 106.0 | 113.0 | |
Operating Range Cooling/Heating | °C | -5.0 to 46.0/ -25.0 to 15.5 |
-5.0 to 46.0/ -25.0 to 15.5 |
-5.0 to 46.0/ -25.0 to 15.5 |
-5.0 to 46.0/ -25.0 to 15.5 |
-5.0 to 46.0/ -25.0 to 15.5 |
|
Cooling | Power Consumption | kW | 24.3 | 26.6 | 28.6 | 28.9 | 31.6 |
EER/SEER/Energy Efficiency Class (or ηsc %) | 3.23/5.65/223.0 | 3.20/5.50/217.0 | 3.15/5.33/210.2 | 3.30/5.69/224.6 | 3.20/5.56/219.4 | ||
Heating | Power Consumption | kW | 22.6 | 24.1 | 25.8 | 27.0 | 29.9 |
COP/SCOP/Energy Efficiency Class (or ηsc(A) %) | 3.88/3.69/144.6 | 3.94/3.60/141.0 | 3.88/3.70/145.0 | 3.93/3.64/142.6 | 3.78/3.64/142.6 | ||
Fan(s) | Standard Air Flow H | l/s | 3500 + 3389 | 3500 + 3389 | 3500 + 3500 | 4806 + 3500 | 4972 + 3500 |
Standard Air Flow H | m3/h | 12600 + 12200 | 12600 + 12200 | 12600 + 12600 | 17300 + 12600 | 17900 + 12600 | |
External Static Pressure | Pa | 40 | 40 | 40 | 40 | 40 | |
Sound | Pressure Level C/H | dB(A) | 64/66 | 64.5/66.5 | 65/67 | 64.5/66 | 64.5/66.5 |
Power Level C/H | dB(A) | 83.5/85.5 | 83.5/85.5 | 84/86 | 84/86 | 84.5/86.5 | |
Unit(s) | Height x Width x Depth | mm | 1830 x 2220 x 780 | 1830 x 2440 x 780 | 1830 x 2440 x 780 | 1830 x 2830 x 780 | 1830 x 2830 x 780 |
Weight | kg | 300 + 242 | 300 + 300 | 300 + 300 | 371 + 300 | 371 + 300 | |
Refrigerant Base Charge | kg | 11.5 + 11.5 | 11.5 + 11.5 | 11.5 + 11.5 | 11.5 + 11.5 | 11.5 + 11.5 | |
Pipe Connections | Suction Gas Pipe Brazing | inch | 1-3/8 | 1-3/8 | 1-3/8 | 1-3/8 | 1-5/8 |
Liquid Pipe Flare | inch | 3/4 | 3/4 | 3/4 | 3/4 | 7/8 | |
Balance Pipe Flare | inch | 3/8 | 3/8 | 3/8 | 3/8 | 3/8 | |
Maximum | Equivalent Length | m | 220 | 220 | 220 | 220 | 220 |
Real Length | m | 180 | 180 | 180 | 180 | 180 | |
Total Pipe Length (Liquid Line Real Length) | m | 300 | 300 | 300 | 1000 | 1000 | |
Length To First Branch | m | 100 | 100 | 100 | 100 | 100 | |
Equivalent Length Of Outdoor Unit Connecting Pipe | m | 10 | 10 | 10 | 10 | 10 | |
Real Length Of Indoor Unit Connecting Piping | m | 30 | 30 | 30 | 30 | 30 | |
Equivalent Length Between Branches | m | 50 | 50 | 50 | 50 | 50 | |
Height Difference Outdoor Higher Than Indoor Units | m | 70 | 70 | 70 | 70 | 70 | |
Height Difference Outdoor Lower Than Indoor Units | m | 40 | 40 | 40 | 40 | 40 | |
Height Difference Between Indoor Units | m | 40 | 40 | 40 | 40 | 40 | |
Height Difference Between Outdoor Units | m | 5 | 5 | 5 | 5 | 5 | |
Electrical | Voltage Range Minimum/Maximum | V | 342/456 | 342/456 | 342/456 | 342/456 | 342/456 |
Electrical Characteristic Run Current Cooling/Heating | A | 37.90/35.20 | 41.90/38.00 | 44.80/40.40 | 45.30/42.30 | 49.20/46.30 | |
Power Supply Wiring Starting Current | Soft Start | Soft Start | Soft Start | Soft Start | Soft Start | ||
Power Supply | V/ph/Hz | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | 380-415/3/50 | |
Suggested Fused Supply(s) | A | 40 + 25 | 40 + 32 | 40 + 40 | 40 + 40 | 40 + 40 |
Reviews