Wall Mounted Split Systems – Standard Inverter R410A

From: £700.00£1,673.00


Note: All systems must be installed by Certified Installer.

Description

Indoor Units FTXS20K FTXS25K FTXS35K FTXS42K FTXS50K FTXS60G FTXS71G
Capacity UK Total Cooling kW 1,95 2,44 3,42 4,11 4,56 5,86 6,94
UK Sensible Cooling kW 1,65 1,82 2,56 2,85 3,14 3,87 4,65
Nominal Cooling kW 2,0 2,5 3,5 4,2 5,0 6,0 7,1
Nominal Heating kW 2,5 3,4 4,0 5,4 5,8 7,0 8,2
Seasonal Efficiency (EN14825) COOLING Energy Label A++ A++ A++ A++ A++ A A
Pdesign kW 2,0 2,5 3,5 4,2 5,0 6,0 7,1
SEER 7,40 7,90 7,47 6,80 6,80 5,58 5,23
Annual Energy Consumption kWh 95 111 164 216 257 376 475
Seasonal Efficiency (EN14825) HEATING Energy Label A++ A++ A++ A+ A+ A A
Pdesign kW 2,3 2,5 3,5 4,0 4,6 4,8 6,5
SCOP 4,77 4,78 4,85 4,20 4,20 3,89 3,50
Annual Energy Consumption kWh 675 732 1039 1334 1535 1728 2593
Nominal Efficiency EER/COP 4.65 / 4.72 4.39 / 4.67 4.07 / 4.76 3.56 / 4.12 3.55 / 4.00 3.02 / 3.43 3.02 / 3.22
Air Flow Rate (Cooling) High / Nom / Low / Silent m3/sec 0.147 / – / 0.078 / 0.065 0.152 / – / 0.083 / 0.065 0.187 / – / 0.097 / 0.068 0.187 / – / 0.117 / 0.068 0.198 / – / 0.123 / 0.075 0.267 / – / 0.188 / 0.168 0.287 / – / 0.192 / 0.175
Dimensions Height mm 289 289 298 298 298 290 290
Width mm 780 780 900 900 900 1050 1050
Depth mm 215 215 215 215 215 250 250
Weight kg 8 8 11 11 11 12 12
Sound Pressure (Cooling) High/Nom/Low/Silent dBA 40 / 32 / 24 / 19 41 / 33 / 25 / 19 45 / 37 / 29 / 19 45 / 39 / 33 / 21 46 / 40 / 34 / 23 45 / 41 / 36 / 33 46 / 42 / 37 / 34
Sound Pressure (Heating) High/Nom/Low/Silent dBA 40 / 32 / 27 / 19 40 / 32 / 27 / 19 41 / 33 / 27 / 19 41 / 33 / 27 / 19 45 / 37 / 29 / 19 44 / – / 35 / 32 46 / – / 37 / 34
Sound Power (Cooling) dBA 58 58 59 59 60 60 63
Outdoor Units RXS20L3 RXS25L3 RXS35L3 RXS42L RXS50L RXS60L RXS71F8
Dimensions HeightxWidthxDepth mm 550 x 765 x 285 550 x 765 x 285 735 x 825 x 300 770 x 900 x 320
Weight kg 34 34 34 39 47 48 71
Electrical Details Power Supply 1ph 1ph
Running Current A 2,30 3,10 4,10 5,70 6,30 8,80 10,49
Starting Current A 2,4 3,3 4,3 6,6 6,8 9,4 11,7
Max Fuse Size A 10 10 10 20 20 20 20
Interconnection Wiring       Core / Cable size 3+E / 1.5 3+E / 1.5
Piping Connections            Liquid / Gas inches (mm) 1/4 (6.4) / 3/8 (9.5) 1/4 (6.4) / 1/2 (12.7) 1/4 (6.4) / 5/8 (15.9)
Pipework Maximum Length m 20 20 20 20 30 30 30
Maximum Vertical Rise m 15 15 15 15 20 20 20
Precharged to m 10 10 10 10 10 10 10
Additional Charge g/m 20 20
Holding Charge kg 1,00 1,00 1,20 1,30 1,70 1,50 2,30
Sound Pressure (Cooling)    High / Low / Silent dBA 46 / 43 46 / 43 48 / 44 48 / 44 48 / 44 49 / 46 52 / 49
Sound Pressure (Heating)    High / Low / Silent dBA 46 / – / 43 46 / – / 43 48 / – / 45 48 / – / 45 48 / – / – 48 / – / – 52 / – / 49
Sound Power (Cooling) 59 59 61 61 62 62 65
Operating Range (Cooling)   Min / Max °CDB -10 / 46 -10 / 46 -10 / 46 -10 / 46 -10 / 46 -10 / 46 -10 / 46
Operating Range (Heating)  Min / Max °CWB -15 / 18 -15 / 18 -15 / 18 -15 / 18 -15 / 18 -15 / 18 -15 / 18
Air Flow Rate (Cooling)        High m3/sec 0,558 0,558 0,600 0,621 0,848 0,835 0,910

Reviews

There are no reviews yet.

Be the first to review “Wall Mounted Split Systems – Standard Inverter R410A”

Your email address will not be published. Required fields are marked *

Downloads

No files uploaded.